Eave and Gable Extensions

STC-MSC Gable Ext Tail End -Field Bend Vertical Leg-Term Trim w NO Soffit and Thermal Spacer

1

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

GABLE EXTENSION DIMENSION

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

BL

TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) NOTE: FIELD FORM A 3" VERTICAL ROOF PANEL LEG TO FIT FINAL DIMENSION

TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) RAKE SUPPORT (A-20-T)

* NOTE: IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDER FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.

PURLIN

PURLIN STC/MSC ROOF PANEL THERMAL SPACER PURLIN CLOSURE (GPC) PANEL CLIP w/FASTENERS

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

* 1/4-14 X 1 1/4" SHOULDER (24" C.C.) RAKE SUPPORT (A-20-T) GABLE TRIM (GTM)

RAKE ANGLE (A-20-B)

(2) #12-14 X 1 1/4"' PER CLOSURE

(NOT BY CHIEF)

TOP VIEW

RAKE ANGLE (A-20-B) FIELD NOTCH AS REQUIRED AT EACH PURLIN ROW #12-14 X 1" PANCAKE HEAD (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE

#12-14 X 1" PANCAKE HEAD (2 PER PURLIN) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

**

INSIDE CLOSURE

(2) 1/4-14 X 7/8"

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C.for AP PANEL) 1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT)

GABLE EXPANSION TRIM (GET)

EAVE STRUT

1/4-14 X 7/8" (12" C.C.)

GABLE EXTENSION CHANNEL (GEC)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

#12-14 X 1" PANCAKE HEAD EACH PURLIN

WALL PANEL

PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION (NOT BY CHIEF)

#12-14 X 1 1/4" (12" C.C.) EXTENSION FLASHING (EF)

** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

PURLIN CLOSURE INSTALLATION

Made with FlippingBook flipbook maker