Eave and Gable Extensions
STC-MSC Gable Ext Tail End -Term Trim w CS Soffit and Thermal Spacer
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
GABLE EXTENSION DIMENSION
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
BL
TRI-BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (12" C.C. AND FASTEN THROUGH CLIP) TERMINATION TRIM (GTTM) #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION
TRI-BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.) 1/4-14 X 1 1/4" WT (24" C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) RAKE SUPPORT (A-20-T) GABLE TRIM (GTMC) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) 1/4-14 X 7/8" (12" C.C.) GABLE EXTENSION CHANNEL (GEC) GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) (2) 1/4-14 X 7/8"
PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN)
PURLIN
PURLIN
STC/MSC ROOF PANEL THERMAL SPACER PURLIN CLOSURE (GPC)
(NOT BY CHIEF)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
(NOT BY CHIEF)
PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN #12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)
(2) #12-14 X 1 1/4"' PER CLOSURE
TOP VIEW
CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.)
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR)
EAVE STRUT
JAMB TRIM (JT)
INSIDE CLOSURE **
EXTENSION FLASHING (EFC)
1/4-14 X 7/8" (12" C.C.)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)
WALL PANEL
#12-14 X 1" PANCAKE HEAD EACH PURLIN #12-14 X 1 1/4" (12" C.C.)
* It is important that 1/4-14 x 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support. DRAFTING NOTE: ** Inside closure must be provided on buildings with liner insulation system.
PURLIN CLOSURE INSTALLATION