Eave and Gable Extensions
MVF-MVP Low Side Eave Ext w Oversize Gutter CS-AP Soffit and Thermal Spacer
NOTE: If intermediate purlin is required, chg purlin, all fasteners, and pre-glued thermal spacer to "DIM" layer.
OVERSIZE GUTTER (EGMO- ) #12-14 X 1 1/4" (EACH STRAP) TRIM COLOR * 1/4-14 X 1" (EACH STRAP) FLAT STRAP (GSMO-) (2'-8" C.C AT PANEL HI-RIBS) 1/4-14 X 7/8" WT (6" C.C.) (1/4-14 X 1 1/4" WT AT STRAP LOCATIONS) TAPE MASTIC
MVF/MVP ROOF PANEL 1/4-14 X 1 1/4" WT (4 PER PANEL) ** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System. PANEL CLIP w/FASTENERS PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION (NOT BY CHIEF)
GUTTER STRAP (GSM) (2'-8" C.C. AT PANEL HI-RIBS) 1/4-14 X 1 1/4" WT (4 PER PANEL)
BL
(2) 1/4-14 X 7/8" WT
"PIG TAIL" TAPE MASTIC (BETWEEN PANELS)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
* Field drill 1/4" dia. hole in special gutter strap, field drill 1/8" dia. pilot hole in flat strap if required.
** INSIDE CLOSURE
#12-14 X 1 1/4" (12" C.C.) (TYP.) EXTENSION FLASHING (EF) EAVE EXTENSION FLASHING (EEFA) 1/4-14 X 7/8" (12" C.C.)
OUTSIDE CLOSURE
DOUBLE BEAD TAPE MASTIC
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) SOFFIT TRIM (ESTO) 1/4-14 X 7/8" (12" C.C.) WALL PANEL
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)
PANEL OVERHANG
GUTTER STRAP LAP
GUTTER PROFILE EGM0
PITCH
SOFFIT PANEL
<=3/4:12 >3/4:12 to <=1 1/2:12 >1 1/2:12 to <=2 1/2:12 >2 1/2:12 to <=3 1/2:12 >3 1/2:12 to <=4 1/2:12
3 3/4 3 1/2
7 1/8 6 11/16
OUTSIDE CLOSURE 1/4-14 X 7/8" (12" C.C.)
EGM1
EGM2
3 1/4
6 3/8
EGM3
2 7/8
5 11/16
EGM4
3 1/2
5 5/8
All Dimensions in Inches
Made with FlippingBook flipbook maker