Eave and Gable Extensions

MVF-MVP High Side Eave Ext w Eave Trim NO Soffit and Thermal Spacer

NOTE: Jamb trim around extension beam as required.

PANEL CLIP w/FASTENERS *1/4-14 X 7/8" WT DOUBLE BEAD TAPE MASTIC PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION

5"

PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN) MVF/MVP ROOF PANEL

RIDGE CLOSURE

BL

1/4-14 X 7/8" WT (7 PER PANEL) DOUBLE BEAD TAPE MASTIC

(NOT BY CHIEF)

THERMAL SPACER (NOT BY CHIEF)

** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.

HI-SIDE EAVE TRIM (HSEVC)

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

1/4-14 X 7/8" (12" C.C.) HIGH SIDE EAVE EXTENSION FLASHING (HEEF)

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

**

INSIDE CLOSURE

* For screw spacing refer to High Side detail in the MVF/MVP Roof Panel Erection manual.

1/4-14 X 7/8" (12" C.C.)

PANEL CAP TRIM (SCT)

WALL PANEL