MSC - Erection Manual
MSC M echanically S eamed C onstruction
®
DETAILS
ENDLAP
7"
3"
4"
1/4"-14 X 1 1/4" WT (9) PER PANEL
1 1/2"
UPPER MSC PANEL
LOWER MSC PANEL
PRE-CUT TRI-BEAD TAPE MASTIC
BACK-UP PLATE
INSULATION PANEL CLIP W/FASTENERS (SEE ROOF PANEL PLAN)
1/4"-14 X 1 1/4" WT
PURLIN
FIELD LOCATED
MSC PANEL
1/4"-14 X 1 1/4" WT
BACK-UP PLATE
ENDLAP END VIEW
FASTENER LOCATIONS
MSC-44