DETAILS RAKE TRIM ENDING RAKE OFF MODULE (TERMINATION TRIM)
TERMINATION TRIM (GTTM)
TRI-BEAD TAPE MASTIC
1/4"-14 X 7/8" WT (6" C.C.)
1/4"-14 X 1 1/4" WT (12" C.C.) (1 FASTENER THROUGH CLIP)
TRI-BEAD TAPE MASTIC
INSULATION (BY INSULATION SUPPLIER) MSC PANEL PANEL CLIP W/FASTENERS (SEE ROOF PANEL PLAN)
#12-14 X 1 1/4" (6" C.C. for CS Panel) (12" C.C. for AP Panel) GABLE TRIM (GTMC) RAKE SUPPORT 1/4"-14 X 1 1/4" WT (24" C.C.)
(2)1/4"-14 X 7/8" RAKE ANGLE (A-20-B)
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
#12-14 X 1" PANCAKE HEAD (2 PER PURLIN)
*1/4"-14 X 1 1/4" SHOULDER (2'-0" C.C.)
GABLE EXPANSION TRIM (GET)
1/4"-14 X 7/8" (12" C.C.)
PURLIN
OUTSIDE CLOSURE
BL
(2) 1/4"-14 X 7/8" WT
WALL PANEL
**TERMINATION TRIM PLUG
* It is important that 1/4"-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support. **Terrmination Trip Plug is field formed using Termination Trim scrap. Apply sealant as required.
(2) 1/4"-14 X 7/8" WT
TRIM CAP (TCM)
Termination Trim Plug at Eave