GABLE RIDGE TRIM (Cont'd.)
5. Install roof cap flush with gable ridge trim face.
ROOF CAP
ROOF PANEL
1/4"-14 X 7/8" WT, DO NOT FASTEN ROOF CAP TO GABLE RIDGE TRIM.
GABLE TRIM
(2)1/4"-14 X 7/8"
GABLE RIDGE TRIM
GABLE TRIM
ROOF CAP PLUG
BEAD OF SIKA 511
6. Place a bead of Sikalastomer-511 all around the top legs of the roof cap plug. Place a bead of Sikalastomer-511 across the inside face of the bottom leg. Fasten roof cap plug to the roof cap with (8)1/4"-14 x 7/8" WT fasteners (2 per leg) and (2)1/4"-14 x 7/8" fasteners to gable ridge trim.
MSC-54