MSC - Erection Manual
MSC
®
M echanically S eamed C onstruction
SPECIAL ERECTION TECHNIQUES VENTED RIDGE w/Vent Material
1/4"-14 X 7/8" WT
RIDGE FLASHING
4"
1/4"-14 X 7/8" WT (6" C.C.)
12"
8"
METAL VENT
TRI-BEAD TAPE MASTIC TRI-BEAD TAPE MASTIC MSC ROOF PANEL
VENT MATERIAL
RIDGE CLOSURE
BACK-UP PLATE
1/4"-14 X 1 1/4" WT (9) PER PANEL
INSULATION
PANEL CLIP W/FASTENERS (SEE ROOF PANEL PLAN) PURLIN
CUT LINE
6"
CAULK ON THE INSIDE WITH SIKA-201
RIDGE FLASHING
1 ½"
1 ½"
1 ½"
1 ½"
5 ¼"
24" Panels = 4 SPACES AT 5 ¼" 18" Panels = 3 SPACES AT 5"
OUTSIDE CLOSURE
1/4"-14 X 7/8" WT
RIDGE FLASHING FASTENER SPACING
NOTE: Extend metal vent material 6" past the gable trim. Field slit and bend back to fill area between vertical face of vent and the ridge flashing plug. Caulk where endcap is formed with SIKA-201.
SUBJECT TO CHANGE WITHOUT NOTICE
MSC-63
Version 7.2