MVF / MVP - Erection Manual
MVF/MVP M echanically S eamed V ertical Leg F lat M echanically S eamed V ertical Leg P encil-rib
®
ERECTION SEQUENCE
STEP 6
1
ENDLAP - PANEL
NOTE Step 6 applies only where more than one panel is used in a single slope.
5"
BOTTOM ROOF PANEL
SIKA-511
Using Sikalastomer-511 sealant, apply a 1/4” to 5/16” wide bead on the bottom panel as shown.
SUBJECT TO CHANGE WITHOUT NOTICE CAUTION The roof should be swept clean of any drill shavings at the end of each day to prevent rust.
MVF/MVP-28
Version 2.0
Made with FlippingBook - Online catalogs