STC - Erection Manual
STC
®
S nap T ight C onstruction
DETAILS EAVE GUTTER TRIM
(2)1/4"-14 X 7/8" WT
GUTTER STRAP (GSM)
2" STRIP OF TRI-BEAD TAPE MASTIC UNDER EACH FASTENER
STC PANEL
1/4"-14 X 1 1/4" WT (8) PER PANEL
2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS
(2)1/4"-14 X 7/8" WT
SEE ERECTION DRAWINGS
TRI-BEAD TAPE MASTIC DOUBLE BEAD TAPE MASTIC
2" STRIP OF TRI-BEAD TAPE MASTIC UNDER EACH FASTENER
SEE ERECTION DRAWINGS
TRAP RIB PLUG (TRP)
INSIDE CLOSURE
DOUBLE BEAD TAPE MASTIC GUTTER STRAP (GSM)
STC PANEL
#12-14 X 1 1/4"
(2)1/4"-14 X 1" PER CLOSURE
TRI-BEAD TAPE MASTIC
GUTTER (EGM) 1/4"-14 X 7/8" WT (6" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS Panel) (12" C.C. for AP Panel)
1/4"-14 X 7/8" (12" C.C.)
TRIM CAP (TCM)
EAVE STRUT WALL PANEL
Refer to erection drawing General Details for expansion joint installation instructions if required.
BL
SUBJECT TO CHANGE WITHOUT NOTICE
Version 7.1
STC-39