STC - Erection Manual
STC
®
S nap T ight C onstruction
DETAILS
LOW EAVE TRIM
1/4"-14 X 1 1/4" WT (8 PER PANEL)
SEE ERECTION DRAWINGS
2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS
TRI-BEAD TAPE MASTIC
INSIDE CLOSURE (2)1/4"-14 X 1" (EACH CLOSURE)
1/4"-14 X 7/8" WT (5 PER PANEL)
DOUBLE BEAD TAPE MASTIC
TRAPEZOID TRIM PLUG (TRP)
STC PANEL
TRI-BEAD TAPE MASTIC
DOUBLE BEAD TAPE MASTIC
EAVE TRIM
#12-14 X 1 1/4" (6" C.C. for CS Panel) (12" C.C. for AP Panel)
1/4"-14 X 7/8" (12" C.C.)
TRIM CAP
INSULATION
1/4"-14 X 7/8" (12" C.C.)
EAVE STRUT
OUTSIDE CLOSURE
WALL PANEL
BL
Refer to erection drawing General Details for expansion joint installation instructions if required.
NOTE: THIS OPTIONAL EAVE TRIM IS AVAILABLE. HOWEVER, UNDER CERTAIN CONDITIONS IT MAY INDUCE STAINING OF WALL PANELS.
SUBJECT TO CHANGE WITHOUT NOTICE
Version 7.1
STC-43