STC MSC Roof Panel
STC-MSC Eave Isometric w Eave Trim
STC/MSC ROOF PANEL
(19) 1/8" X 3/8" BLIND RIVETS
STC/MSC ROOF PANEL
GABLE TRIM (GTM)
GABLE TRIM (GTM)
*DOUBLE BEAD TAPE MASTIC
EAVE TRIM (ETM)
*TRAPEZOID PLUG (TRP)
(12) 1/8" X 3/8" BLIND RIVETS
GABLE TRIM PLUG (TPRM/TPLM)
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
GABLE CORNER TRIM (GCTM)
2" STRIP OF MINOR RIB TAPE SEALER (TYP.)
NOTE: 1. START GABLE TRIM BOTTOM LEG 4" OUT FROM SIDEWALL BUILDING LINE. 2. START EAVE TRIM 3" OUT FROM ENDWALL BUILDING LINE. 3.) LOCATE GABLE TRIM PLUG AGAINST HIGH-RIB OF CS ENDWALL PANEL OR FLAT OF AP ENDWALL PANEL. 4. FIELD CUT ROOF PANEL AT GABLE CORNER TRIM. (AS REQUIRED) 5. USE SIKA 511 SEALANT AT PLUG AND GABLE CORNER TRIM TO EAVE TRIM. GABLE CORNER TRIM WITH EAVE TRIM
GABLE EXPANSION TRIM (GET)
NOTE: 1. USE 1 1/2" LAP AT SPLICES, AND FIELD CUT 3/8" LOCKFORM AT SPLICE. 2. FASTEN SPLICE WITH (12) 1/8" X 3/8" BLIND RIVETS. 3. USE SIKA 511 SEALANT AT SPLICE.
EAVE TRIM (ETM)
*EDGE OF MASTIC ALIGNS WITH FACE OF TRAPEZOID PLUG
DOUBLE BEAD TAPE MASTIC
GABLE TRIM SPLICE
TRAPEZOID PLUG INSTALLATION WITH EAVE TRIM
Made with FlippingBook flipbook maker