STC MSC Roof Panel
MSC 2-Inch-Gable End-Field Bend Vertical Leg-Termination Trim-Thermal Spacer
TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) 1/4-14 X 7/8" WT (6" C.C.) TRI-BEAD TAPE SEALER GABLE TRIM (GTMC) RAKE SUPPORT (A-20-2) RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1/4-14 X 1 1/4" SHOULDER (24" C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) * 1/4-14 X 1 1/4" WT (12" C.C.) RAKE SUPPORT (A-20-2) TRI-BEAD TAPE SEALER MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)
BL
THERMAL SPACER
(NOT BY CHIEF)
***
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) RAKE ANGLE (A-20-B) #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
(2) 1/4-14 X 7/8" INSIDE CLOSURE
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.) **OUTSIDE CLOSURE WALL PANEL
* It is important that 1/4-14 X 1 1/4" SHOULDERS are installed through the center of the slotted holes of the rake support.
**NOTE: Field cut outside closure for higher roof pitches.
Made with FlippingBook flipbook maker