STC MSC Roof Panel

MSC 2-Inch-Inset Gable Tail Height Change-Special Trim-Panel Below-Thermal Spacer

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

INSIDE CLOSURE SPECIAL TRIM (SPT- ) #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) TRI-BEAD TAPE MASTIC

CLOSURE CLIPS (GCC-1) (TYP.)

BL

PURLIN CLOSURE (TYP.)

*WALL PANEL

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

PURLIN

SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING) (SEE INSET DETAIL)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

1

4 "

THERMAL SPACER MSC ROOF PANEL

(2) #12-14 X 1 1/4"' PER CLOSURE

(NOT BY CHIEF)

HEIGHT CHANGE ANGLE (A-20-H)

TOP VIEW

HEIGHT CHANGE TRIM BOTTOM (GHMBF) 1/4-14 X 1 1/4" WT (12" C.C. AND FASTEN THROUGH CLIP)

PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN) (TYP)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

PURLIN

PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN) HEIGHT CHANGE RAFTER

SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING)

EAVE STRUT

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

PANELING CAP TRIM (SCT) (2) #12-24 X 1 1/2" AT 36" C.C.

RAKE ANGLE (A-20) 1/4-14 X 7/8" (12" C.C.)

PURLIN CLOSURE INSTALLATION