STC MSC Roof Panel
MSC 2-Inch-Inset Gable Height Change-Special Set Back-Field Bend Vertical Leg-Thermal Spacer
** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT. * FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
*WALL PANEL
INSIDE CLOSURE
BL
SPECIAL HEIGHT CHANGE TRIM TOP (SPT- )
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER
SPECIAL HEIGHT CHANGE ANGLE (PL- ) #12-14 x 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1/4-14 X 1 1/4" WT (12" C.C.)
MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)
1
4 "
** 1/4-14 X 1 1/4" SHOULDER (24" C.C.)
THERMAL SPACER
(NOT BY CHIEF)
PURLIN
RAKE SUPPORT (A-20-2) HEIGHT CHANGE TRIM BOTTOM (GHMBF)
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)