STC MSC Roof Panel
MSC 2-Inch-Gable Tail End-Taller Existing Building
COUNTER FLASHING (NOT BY CHIEF)
1
CAULKING (NOT BY CHIEF) SPECIAL TRIM TOP (SPT- ) TRI-BEAD TAPE SEALER
L EXIST. B
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- )(BEFORE ASSEMBLING) (SEE INSET DETAIL)
FASTENER AT 12" C.C. (NOT BY CHIEF)
1/4-14 X 1 1/4" WT (12" C.C.)
(NOT BY CHIEF) ** DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.
** PRE-GLUED THERMAL SPACER
MSC ROOF PANEL
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
RAKE SUPPORT (A-20-2)
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
PURLIN
3"
1/4-14 X 1 1/4" SHOULDER (24" C.C.)* RAKE ANGLE (A-20-B)
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING)
* IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT AND THAT THESE FASTENER MUST NOT HIT THE PURLINS.