STC MSC Roof Panel
STC-MSC Gable Lead End Vertical Leg Set Back from Building Line and Termination Trim
1/4-14 X 1 1/4" SHOULDER (24" C.C.) * TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.) 1/4-14 X 1 1/4" SHOULDER (24" C.C.) * RAKE SUPPORT (A-20-S) STC/MSC ROOF PANEL PRE-GLUED THERMAL SPACER (NOT BY CHIEF) ****
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B) RAKE SUPPORT (A-20-S) GABLE TRIM (GTMC) TRI-BEAD TAPE SEALER 1/4-14 X 7/8" WT (6" C.C.) 1/4-14 X 1 1/4" WT(24" C.C.) TERMINATION TRIM (GTTM)
BL
PURLIN
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) RAKE ANGLE (A-20-B) #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
(2) 1/4-14 X 7/8" INSIDE CLOSURE
***
WALL PANEL **OUTSIDE CLOSURE 1/4-14 X 7/8" (12" C.C.) GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
* It is important that 1/4-14 X 1 1/4" SHOULDERS are installed through the center of the slotted holes of the rake support.
** NOTE: Field cut outside closure for higher roof pitches.
**** DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.