STC MSC Roof Panel

STC-MSC Gable Lead End Thermal Spacer

GABLE TRIM (GTM) RAKE SUPPORT (A-20-T) RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.) 1/4-14 X 1 1/4" SHOULDER 24" C.C.)* STC/MSC ROOF PANEL THERMAL SPACER

1

BL

(NOT BY CHIEF)

INSIDE CLOSURE

***

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM. * It is important that 1/4-14 X 1 1/4" SHOULDERS are installed through the center of the slotted holes of the rake support.

(2) 1/4-14 X 7/8"

GABLE EXPANSION TRIM (GET) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)

1/4-14 X 7/8" (12" C.C.)

WALL PANEL **OUTSIDE CLOSURE

** NOTE: Field cut outside closure for higher roof pitchs.