STC MSC Roof Panel
STC-MSC Inset Gable Height Change w Field Bend Vertical Leg
* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
INSIDE CLOSURE HEIGHT CHANGE TRIM TOP (GHMTF) TRI-BEAD TAPE SEALER
HEIGHT CHANGE ANGLE (A-20-H) * WALL PANEL
BL
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1/4-14 X 1 1/4" WT (12" C.C.)
***
RAKE SUPPORT (A-20-S)
PRE-TAPED THERMAL SPACER (NOT BY CHIEF)
STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)
*** DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION.
1
4 "
PURLIN
2"
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.
**1/4-14 X 1 1/4" SHOULDER (24" C.C.)
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)