STC MSC Roof Panel

STC-MSC Outset Gable Tail Height Change w Special Trim- Panel Below and Thermal Spacer

PURLIN

INSIDE CLOSURE SPECIAL TRIM TOP (SPT- ) TRI-BEAD TAPE MASTIC

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

BL

PURLIN CLOSURE (TYP.)

*WALL PANEL

* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.

HEIGHT CHANGE ANGLE (A-20-H)

SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING) (SEE INSET DETAIL) 1/4-14 X 1 1/4" WT (12" C.C. AND FASTEN THROUGH CLIP)

#12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

PURLIN

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

THERMAL SPACER STC/MSC ROOF PANEL

(2) #12-14 X 1 1/4"' PER CLOSURE

(NOT BY CHIEF)

PURLIN

1

4 "

TOP VIEW

HEIGHT CHANGE TRIM BOTTOM (GHMBF)

PANEL CLIP AND FASTENERS

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN CLOSURE (GPC___) (PURLIN CLOSURE CLIPS NOT SHOWN)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

1/4-14 X 7/8" (12" C.C.) #12-14 X 1 1/4" (GA) (2 EACH PURLIN)

EAVE STRUT

PANELING CAP TRIM (SCT)

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

RAKE ANGLE (A-20)

HEIGHT CHANGE RAFTER

SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING)

PURLIN CLOSURE INSTALLATION

Made with FlippingBook flipbook maker