STC MSC Roof Panel
STC-MSC Gable Tail End to Taller Existing Building and Thermal Spacer
COUNTER FLASHING (NOT BY CHIEF) CAULKING (NOT BY CHIEF) SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLY) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER SPECIAL TRIM TOP (SPT- )
1
L EXIST. B
FASTENER AT 12" C.C. (NOT BY CHIEF)
1/4-14 X 1 1/4" WT (12" C.C.) THERMAL SPACER STC/MSC ROOF PANEL
(NOT BY CHIEF)
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
RAKE SUPPORT (A-20-T)
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
3"
PURLIN
1/4-14 X 1 1/4" SHOULDER (24" C.C.) * RAKE ANGLE (A-20-B)
SIKA 511 CAULK IN LOCKFORM OF SPECIAL TRIM TOP (SPT- ) (BEFORE ASSEMBLING)
* IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT AND THAT THESE FASTENER MUST NOT HIT THE PURLINS.