STC MSC Roof Panel
STC-MSC Gable End w Field Bend Vertical Leg and Nichiha Panel Not by Chief
SPECIAL GABLE TRIM (SPT-X)
1
TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B) RAKE SUPPORT (A-20-S)
BL
* 1/4-14 X 1 1/4" SHOULDER (24" C.C.) STC/MSC ROOF PANEL (FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)
(2) FASTENERS (NOT BY CHIEF) SPECIAL PURCHASED (IF BY CHIEF)
***
PRE-GLUED THERMAL SPACER (NOT BY CHIEF)
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET)
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN
FASTENERS (NOT BY CHIEF) (12" C.C.)
SPECIAL PURCHASED (IF BY CHIEF)
WALL PANEL
** NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL PANEL IS NOT BY CHIEF. * IT IS IMPORTANT THAT 1/4-14 X 1 1/4" SHOULDERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.
** _" NICHIHA PANEL (NOT BY CHIEF)
***DRAFTING NOTE: THERMAL SPACER TO BE USED WITH NO INSULATION