Special Features

Canopy MSC-STC Roof Eave Gutter w FSP Soffit

NOTES: * Field cut (2) 2" long strips of tri-bead tape mastic & center under 1/4-14 x 7/8" WT's between gutter strap and roof panel. ** See Isometric Trapezoid Plug Installation detail for installation instructions. *** For screw spacing refer to High Side Height Change detail in the MSC/STC Roof Panel Erection Manual. **** 24" STC - Pre-Cut Tri-Bead Tape Mastic. 24" MSC - Tri-Bead Tape Mastic from roll. 18" MSC/STC - Tri-Bead Tape Mastic from roll. ***** Provide air gap of 1/4" min. at bottom of panel to avoid corrosion. ****** Purlin is a typical example. See Canopy framing drawings for required number of purlin rows.

BL

X'-X"

RAKE ANGLE (A-20-B) WALL PANEL (TYP.) #12-14 X 1 1/4" (TYP.) (6" C.C. for CS PANEL) (12" C.C for AP PANEL)

TRI-BEAD TAPE MASTIC ***1/4-14 X 7/8" WT HEIGHT CHANGE TRIM (LHET) INSIDE CLOSURE

*(2) 1/4-14 X 7/8" WT GUTTER STRAP TO ROOF PANEL 2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS 1/4-14 X 1 1/4" WT PANEL TO EAVE (8 PER PANEL)

****TRI-BEAD TAPE MASTIC OUTSIDE CLOSURE 1/4-14 X 1 1/4" WT (9 PER PANEL) PRE-TAPED THERMAL SPACER PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)

***** 1 4 "

**TRAPEZOID PLUG (TRP) EACH HIGH RIB TRI-BEAD TAPE MASTIC (TOP AND BOTTOM)

4 1

2 "

HEIGHT CHANGE GIRT (2) #12-14 X 1 1/4" (GA) (36" C.C.)

DOUBLE BEAD TAPE MASTIC (TOP AND BOTTOM) GUTTER STRAP (GSM) AT EACH PANEL HI-RIB

STC/MSC CANOPY ROOF PANEL

(NOT BY CHIEF)

BACK-UP PLATE

4"

8"

1/4-14 X 1" (2) PER CLOSURE METAL INSIDE CLOSURE

#12-14 X 1 1/4" (TRIM COLOR)

1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) OUTSIDE CLOSURE SOFFIT TRIM (SBLTO) 1/8" X 3/8" BLIND RIVET (12" C.C.)

EAVE GUTTER (EGM) 1/4-14 X 7/8" WT (6" C.C.)

EAVE STRUT

#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.) 1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR) ****** CANOPY PURLIN (TYP.)

#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)

1/4-14 X 7/8" (EACH RIB) (SOFFIT COLOR)

CANOPY EAVE FLASHING (GELA)

CANOPY EAVE BOTTOM FLASHING (GLBA) 1/4-14 X 7/8" (12" C.C.)

DRAFTING NOTE: ยท 26 GA FSP soffit must always have 1/4-14 x 7/8" fasteners located at ribs at end supports. change fasteners to "DIM" layer.

FSP SOFFIT PANEL