Special Features
Eave Strut to Col w 10 Flange and STC-MSC Roof Trans Exp w Thermal Spacer
* FINGER TIGHTEN 1ST 1/2" DIA. NUT TO HARD WASHER, WRENCH TIGHTEN SECOND NUT TO FIRST NUT TO CREATE A SLIDING CONNECTION
SPECIAL PUNCH 9/16" HOLES AT 1 3/8" DIM A AND 4 1/4" GAGE IN BOTH EAVE STRUTS
*** NOTCH AND FIELD BEND TAB ON RAKE ANGLE, FASTEN TO EAVE STRUT LIP AS SHOWN
1
** MAINTAIN 3 1/2" BETWEEN FIXED AND SLIDING EAVE STRUT DURING BUILDING ERECTION
(2) #12-14 X 1 1/4" (TYP.) (WALL COLOR) RAKE ANGLE (A-20-B)
CL
(2) #12-14 X 1 1/4" SLIDING EAVE STRUT TOP OF PURLIN LINE
4 1 2 " 1 1 4 "
REF PT
1"
(4) 1/2" X 1 1/4" BOLTS
SLIDING PURLIN (2) #12-14 X 1" PANCAKE HEAD (2) PER PURLIN ***RAKE ANGLE (A-20-B)
1 1 4 "
1 3 8 " 4 1 4 "
SLIDING EAVE STRUT XBC-97 * (2) 1/2" X 1 3/4" BOLTS w (2) NUTS AND (1) 1/2" HARD WASHER AT EACH SLOT (BOLT MUST BE CENTERED IN SLOT)
EAVE HEIGHT
EAVE HEIGHT
* (2) 1/2" X 1 3/4" BOLTS w/ (2) NUTS AND (1) 1/2" HARD WASHER XBC-96
**3 1 2 "
3 1 4 "
FIXED EAVE STRUT
(4) 5/8" X 1 1/2" BOLTS w/ 5/8" HARD WASHERS AT C-SECTION SIDE
SECTION
FRAME COLUMN
Made with FlippingBook flipbook maker