Special Features

Eave Strut to Col w 10 Flange and STC-MSC Roof Trans Exp wo Thermal Spacer

* FINGER TIGHTEN 1ST 1/2" DIA. NUT TO HARD WASHER, WRENCH TIGHTEN SECOND NUT TO FIRST NUT TO CREATE A SLIDING CONNECTION

** MAINTAIN 3 1/2" BETWEEN FIXED AND SLIDING EAVE STRUT DURING BUILDING ERECTION SPECIAL PUNCH 9/16" HOLES AT 1 3/8" DIM A AND 4 1/4" GAGE IN BOTH EAVE STRUTS

** NOTCH AND FIELD BEND TAB ON RAKE ANGLE, FASTEN TO EAVE STRUT LIP AS SHOWN

1

(2) #12-14 X 1 1/4" (TYP.) (WALL COLOR) **RAKE ANGLE (A-20-B)

(2) #12-14 X 1 1/4" SLIDING EAVE STRUT TOP OF PURLIN LINE

CL

4 1 2 " 1 1 4 "

1"

REF PT

(4) 1/2" X 1 1/4" BOLTS

SLIDING PURLIN (2) #12-14 X 1" PANCAKE HEAD (2) PER PURLIN **RAKE ANGLE (A-20-B)

1 1 4 "

1 3 8 " 4 1 4 "

EAVE HEIGHT

EAVE HEIGHT

SLIDING EAVE STRUT XBC-97 * (2) 1/2" X 1 3/4" BOLTS w/ (2) NUTS AND (1) 1/2" HARD WASHER AT EACH SLOT (BOLT MUST BE CENTERED IN SLOT)

* (2) 1/2" X 1 3/4" BOLTS w/ (2) NUTS AND (1) 1/2" HARD WASHER XBC-97

**3 1 2 "

3 1 4 "

FIXED EAVE STRUT

(4) 5/8" X 1 1/2" BOLTS w/ 5/8" HARD WASHERS AT C-SECTION SIDE

SECTION

FRAME COLUMN

Made with FlippingBook flipbook maker