Special Features
Z-Purlin to Rafter 6-8 Flange and MVF-MVP Roof Trans Exp
* FINGER TIGHTEN 1ST 1/2" DIA. NUT TO HARD WASHER, WRENCH TIGHTEN SECOND NUT TO FIRST NUT TO CREATE A SLIDING CONNECTION SPECIAL PUNCH 9/16" HOLES AT 1 3/8" DIM A AND 4 1/4" GAGE IN BOTH PURLINS
* (2) 1/2" X 1 3/4" BOLTS w/ (2) NUTS AND (1) 1/2" HARD WASHER AT SLOT (BOLTS MUST BE CENETERD IN SLOT) (4) 1/2" X 1 1/4" BOLTS
1
CL
1 1 4 "
4 1 2 "
REF PT
SLIDING PURLIN
1 1 4 "
1 3 8 " 4 1 4 "
XBC-96
3 1 4 "
**2 1 2 "
FIXED PURLIN ANGLE FLANGE BRACE (SEE CROSS SECTION FOR PIECE MARK AND BOLTING CONNECTION, INSTALL ONLY ON FIXED PURLIN SIDE)
FRAME RAFTER
** MAINTAIN 2 1/2" BETWEEN FIXED AND SLIDING PURLIN DURING BUILDING ERECTION.