Special Features
STC-MSC Gable Tail - Taller Backup Panel and Thermal Spacer
** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)
HEIGHT CHANGE TRIM TOP (GHMTF) INSIDE CLOSURE w/TAPE MASTIC TOP & BOTTOM
1
**BACK-UP PANEL 1/4-14 X 1 1/4" WT
BL
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
RAKE SUPPORT (A-20-T)
THERMAL SPACER STC/MSC ROOF PANEL 1/4-14 X 1 1/4" WT (12" C.C.)
* It is important that fasteners are installed through the center of the slotted holes of the rake support. TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
(NOT BY CHIEF)
1
4 "
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN HEIGHT CHANGE TRIM BOTTOM (GHMBF) 1/4-14 X 1 1/4" SHOULDER (24" C.C.)*
HEIGHT CHANGE ANGLE (A-20-H)
2"