Special Features
MVF-MVP Height Change at Gable Lead End w Taller Backup Panel and Thermal Spacer
* Field cut bottom of back-up panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
HEIGHT CHANGE TRIM TOP (GHVT)
Tape Mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
MVF/MVP ROOF PANEL DOUBLE BEAD TAPE MASTIC 1/4-14 X 7/8" WT (6" C.C.)** TAPE MASTIC HEIGHT CHANGE TRIM BOTTOM (GHVB) (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
*BACK-UP PANEL INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM 1/4-14 X 1 1/4" WT
BL
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
(NOT BY CHIEF)
THERMAL SPACER
1
4 "
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
PANEL CLIP RAKE ANGLE (A-20-L) #12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
1"
(2) #12-14 X 1 1/4" (WALL COLOR)
**NOTE: This fastener must not hit the purlin.
PURLIN