Special Features
MVF-MVP Height Change w Cut Roof Panel at Gable Lead End - Taller Backup Panel and Thermal Spacer
* Field cut bottom of back-up panels to match roof slope. Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
ROOF PANEL CUT BACK DIM. CLIP LOCATION FROM B
L
HEIGHT CHANGE TRIM BOTTOM (GHVB) HEIGHT CHANGE TRIM TOP (GHVT)
Tape Mastic sent for back-up panel side laps. Warranty fasteners sent for back-up panel.
BL
TAPE MASTIC
*BACK-UP PANEL INSIDE CLOSURE w/TAPE MASTIC TOP & BOTTOM 1/4-14 X 1 1/4" WT
DOUBLE BEAD TAPE MASTIC 1/4-14 X 1 1/4" WT (6" C.C.)** DOUBLE BEAD TAPE MASTIC (2) #12-14 X 1 1/4" (EACH CLIP) WALL COLOR
2 1 4 "
1 1 2 "
(6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
MVF/MVP ROOF PANEL RAKE ANGLE (A-20-B)
PANEL CLIP w/FASTENERS (REFER TO ROOF PANEL PLAN)
1
4 "
PANEL CLIP RAKE ANGLE (A-20-L)
THERMAL SPACER
(NOT BY CHIEF)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
PURLIN
(2) #12-14 X 1 1/4" (WALL COLOR)
**NOTE: This fastener must not hit the purlin.