Special Features
Parapet at High Side w CS - Support Girt
* NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION
PARAPET GIRT PARAPET CAP TRIM (PCT-X) 1/4-14 X 1 1/4" WT (6" C.C.) OUTSIDE CLOSURE 1/4-14 X 7/8" WT (12" C.C.) Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1
BL
* PARAPET CLEAT (PCC-X) #12-14 X 1 1/4" (24" C.C.)
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
XXX'-X"
BACKUP PANEL
INSIDE CLOSURE w/ TAPE MASTIC TOP & BOTTOM HEIGHT CHANGE TRIM (LHTC) 1/4-14 X 7/8" WT (12" C.C.) 1/4-14 X 1 1/4" WT (6" C.C.) OUTSIDE CLOSURE (2" X 3') 2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLOSURE
#12-14 X 1" PANCAKE HEAD (12" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) OUTSIDE CLOSURE
XXX'-X"
DRAFTING USE ONLY: REMOVE EAVE STRUT OR PURLIN W/CORRESPONDING FASTENER AS REQUIRED.
PARAPET/WALL PANEL
1
4 "
CS ROOF PANEL
1 1 2 "
HEIGHT CHANGE GIRT
1/4 -14 X 1 1/4" WT (6"C.C.)
1/4-14 X 1 1/4" WT (6" C.C.) PURLIN
EAVE STRUT
Made with FlippingBook flipbook maker