Special Features
Extended Façade CS Roof Panel w Multi-gutter and Nichiha Panel Not by Chief
HORIZONTAL LEG OF FASCIA CAP TRIM
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
1
DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.
BL
X"
X'-X"
#12-14 X 1 1/4" (24" C.C.)
INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM 1/4-14 X 1 1/4" WT (6" C.C.) BACKUP PANEL 1/4-14 X 7/8" WT (12" C.C.) 1/4-14 X 1 1/4" WT (6" C.C.) FACADE GIRT OUTSIDE CLOSURE
X
SPECIAL CAP TRIM (SPT-X)
** SPECIAL CLEAT (SPT-X)
XXX'-X"
#12-14 X 1 1/4" (CS - 6" C.C.)(AP - 12" C.C.) PANCAKE HEAD FASTENER (NOT BY CHIEF) (12"C.C) SPECIAL PURCHASED (IF BY CHIEF)
INSIDE CLOSURE W/ MASTIC TOP & BOTTOM
GIRT
XXX'-X"
1/4-14 X 1 1/4" WT (4" C.C.) CS ROOF PANEL
* _" NICHIHA PANEL (NOT BY CHIEF) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
#12-14 X 1 1/4" (CS - 6" C.C.)(AP - 12" C.C.)
EAVE STRUT
FASCIA PANEL
* _" NICHIHA PANEL (NOT BY CHIEF) WALL PANEL
*** MULTI-GUTTER (MG-X)
* NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL PANEL IS NOT BY CHIEF.
** NOTE: REFER TO ISOMETRIC PARAPET FACADE CAP TRIM SPLICE DETAIL FOR INSTALLATION
*** Refer to the Multi-Gutter Endcap and Splice detail for installation This run of multi-gutter uses (2) MGEC- as endcaps