Special Features
Parapet at Endwall w CS Roof Panel and Nichiha Panel Not by Chief
DRAFTING: DIMENSION HORIZ. LEG OF CAP TRIM. HAVE PM VERIFY DIM. WITH BLDR.
NOTE: ·
TAPE MASTIC SENT FOR BACK-UP PANEL SIDE LAPS. WARRANTY FASTENERS SENT FOR BACK-UP PANEL.
Field notch the hems 2" to allow for the trim to lap. Leave a two inch space between the cleats at the connection of the parapet cap trim. Apply a 1/4" bead of Sikalastomer-511 and install 10 blind rivets at each joint.
·
HORIZONTAL LEG OF PARAPET CAP TRIM
BL
X"
·
#12-14 X 1 1/4" (24" C.C.)
SPECIAL PARAPET CLEAT (SPT-X)
X"
PARAPET GIRT SPECIAL PARAPET CAP TRIM (SPT-X)
PANCAKE HEAD FASTENER (NOT BY CHIEF) (12" C.C.)
SPECIAL PARAPET CAP TRIM (SPT-X) (OVERLAPPING)
SPECIAL PURCHASED (IF BY CHIEF) XXX'-X"
1/4-14 X 7/8" WT (12" C.C.)
SIKA-511
SPECIAL PARAPET CAP TRIM (SPT-X) (UNDERLAPPING)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
2"
1/4-14 X 1 1/4" WT (6" C.C.) OUTSIDE CLOSURE
2"
1"
PARAPET/WALL PANEL
***BACK-UP PANEL
* _" NICHIHA PANEL (NOT BY CHIEF)
SPECIAL PARAPET CLEAT (SPT-X)
2" GAP
HEIGHT CHANGE ANGLE (A-20-H)
HEIGHT CHANGE TRIM (RHT-X) INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM
SPECIAL PARAPET CLEAT (SPT-X) ISOMETRIC PARAPET / FACADE CAP TRIM SPLICE DETAIL
1/4-14 X 1 1/4" WT (6" C.C.)
1/4-14 X 1 1/4" WT (12" C.C.)
#12 - 14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
DOUBLE BEAD TAPE MASTIC
1
4 "
CS ROOF PANEL
* NOTE: CONNECTION OF NICHIHA PANELS (NOT BY CHIEF), TO WALL PANEL IS NOT BY CHIEF. ** NOTE: FIELD NOTCH RAKE ANGLE ABOUT PARAPET POST AS REQUIRED. RAKE ANGLE IS PROVIDED FOR INSULATION TERMINATION.
*** FIELD CUT BOTTOM OF BACK-UP PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
1 4 "
1"
PURLIN
Made with FlippingBook flipbook maker