Special Steel Framing

Diverter Top View at Bldg Line CS Roof

NOTE: USE 2 ROWS OF INSIDE CLOSURE W/ DOUBLE BEAD MASTIC TOP & BOTTOM AT PANEL / DIVERTER EDGE.

CONTINUOUS Z-PURLIN

(2) 1/2" X 1 1/4" BOLTS (TYP)

SIDE SUPPORT JAMB

UPPER SUPPORT JAMB CS ROOF PANEL

1/4-14 X 1 1/4" WT (6" C.C.)(TYP)

* UPPER SUPPORT JAMB LOCATION

DOWN SLOPE

8"

1"

1'-7" 8"

8"

* 11"

DIVERTER

EAVE STRUT

TAPE SEALANT UNDER ROOF PANEL (BY DIVERTER SUPPLIER)

CUT OFF HORIZONTAL LEG ONLY AS REQUIRED, NOT VERTICAL LEG AT TALLER STRUCTURE (TYP)

1'-0"

DIVERTER WIDTH

TALLER STRUCTURE (NOT BY CHIEF)

DIVERTER ATTACHMENT AND WEATHER TIGHTNESS AT TALLER STRUCTURE (NOT BY CHIEF) IS NOT BY CHIEF.

REFER TO DETAIL BY THE DIVERTER SUPPLIER FOR ADDITIONAL INSTALLATION INSTRUCTIONS. REFER TO OTHER SECTIONS ON THE DRAWINGS FOR ADDITIONAL INSTALLATION INSTRUCTIONS.