Special Steel Framing

Diverter Top View at Bldg Line MSC-STC Roof

CONTINUOUS Z-PURLIN

(2) 1/2" X 1 1/4" BOLTS (TYP)

UPPER SUPPORT JAMB STC / MSC ROOF PANEL DIVERTER SUPPORT J (PL- ) 1/4-14 X 1 1/4" WT (8 PER PANEL)

SIDE SUPPORT JAMB

1/4-14 X 1 1/4" WT (4" C.C.) (TYP)

DOWN SLOPE

8" 1"

3" 5"

EAVE STRUT

METAL INSIDE CLOSURE

1'-7" 8"

1'-2" *

TAPE SEALANT UNDER ROOF PANEL (BY DIVERTER SUPPLIER)

DIVERTER

CUT OFF HORIZONTAL LEG ONLY AS REQUIRED, NOT VERTICAL LEG AT TALLER STRUCTURE (TYP)

1'-0"

DIVERTER WIDTH

TALLER STRUCTURE (NOT BY CHIEF)

* UPPER SUPPORT JAMB LOCATION

DIVERTER ATTACHMENT AND WEATHER TIGHTNESS AT TALLER STRUCTURE (NOT BY CHIEF) IS NOT BY CHIEF.

REFER TO DETAIL BY THE DIVERTER MANUFACTURER FOR ADDITIONAL INSTALLATION INSTRUCTIONS. REFER TO OTHER SECTIONS ON THE DRAWINGS FOR ADDITIONAL INSTALLATION INSTRUCTIONS.