Special Steel Framing

Diverter Side View Corner Diverter MSC-STC Roof

2

REFER TO DETAIL BY THE DIVERTER MANUFACTURER FOR ADDITIONAL INSTALLATION INSTRUCTIONS.

BL

DIVERTER WIDTH

BACKUP PANEL (CONNECTION NOT SHOWN)

1

GIRT (TYP)

EXTERIOR WALL PANEL IS NOT SHOWN

BL

*** FLAT OF PANEL MUST ALIGN WITH DIVERTER SUPPORT J FOR DIVERTER CONNECTION

INSIDE CLOSURE WITH TAPE MASTIC INSIDE AND OUTSIDE

CORNER DIVERTER

DIVERTER SUPPORT J (PL- )

***

STC / MSC ROOF PANEL

1'-0"

DIVERTER HEIGHT

8"

*

CLIP OFFSET

6"

3"

FIELD CUT DIVERTER SUPPORT J AS REQUIRED

* HEIGHT CHANGE TRIM IS NOT SHOWN

THERMAL SPACER (NOT BY CHIEF)

ROOF PANEL IS FOR REFERENCE ONLY REFER TO ROOF PANEL PLAN AND DETAILS FOR CONNECTION.

TAPE SEALER AROUND PERIMETER OF THE DIVERTER / ROOF OPENING (BY DIVERTER SUPPLIER)

PURLIN

SIDE SUPPORT JAMB 1/4-14 X 1" (EACH END AND 12" C.C.)

** 1/4-14 X 1 1/4 WT (4" C.C. AT PANEL / DIVERTER EDGES) ** THESE FASTENERS GO INTO THE SUPPORT J.

REFER TO OTHER SECTIONS ON THE DRAWINGS FOR ADDITIONAL INSTALLATION INSTRUCTIONS.