Special Steel Framing
Diverter Side View Corner Diverter MVF-MVP Roof
2
REFER TO DETAIL BY THE DIVERTER SUPPLIER FOR ADDITIONAL INSTALLATION INSTRUCTIONS.
BL
DIVERTER WIDTH
BACKUP PANEL (CONNECTION NOT SHOWN)
EXTERIOR WALL PANEL IS NOT SHOWN
1
GIRT (TYP)
BL
*** FLAT OF PANEL MUST ALIGN WITH DIVERTER SUPPORT J FOR DIVERTER CONNECTION
INSIDE CLOSURE WITH TAPE MASTIC INSIDE AND OUTSIDE
CORNER DIVERTER
DIVERTER SUPPORT J (PL- )
***
1'-0"
DIVERTER HEIGHT
8"
CLIP OFFSET
MVF / MVP ROOF PANEL
*
6"
* HEIGHT CHANGE TRIM IS NOT SHOWN
3"
THERMAL SPACER (NOT BY CHIEF)
FIELD CUT DIVERTER SUPPORT J AS REQUIRED
ROOF PANEL IS FOR REFERENCE ONLY REFER TO ROOF PANEL PLAN AND DETAILS FOR CONNECTION.
TAPE SEALER AROUND PERIMETER OF THE DIVERTER / ROOF OPENING (BY DIVERTER SUPPLIER)
PURLIN
1/4-14 X 1" (EACH END AND 12" C.C.)
** 1/4-14 X 1 1/4 WT (4" C.C. AT PANEL / DIVERTER EDGES) ** THESE FASTENERS GO INTO THE SUPPORT J.
REFER TO OTHER SECTIONS ON THE DRAWINGS FOR ADDITIONAL INSTALLATION INSTRUCTIONS.
SIDE SUPPORT JAMB