Steel Framing Sections

D26.CORNER COLUMN TO WALL GIRT

* BOLTING CLIP · XBC-74 Clip used for 6"-8" column flange width. · XBC-75 Clip used for 10"-12" column flange width. (Refer to the Wall Elevation drawings)

BL Drafting to verify section

* BOLTING CLIP #12-14 X 1 1/4" (4) 1/2" X 1 1/4" BOLTS GIRT

1 1 2 "

CORNER COLUMN (5) 1/2" X 1 1/4" BOLTS XBC-3 GIRT

GIRT ANGLE (XGA)

#12-14 X 1" PANCAKE HEAD CORNER ANGLE (A-20)

(1)

2 5 8 "

(2)

1 1 2 "

BL

(2) #12-14 X 1 1/4"

GIRT ANGLE (XGA) #12-14 X 1" PANCAKE HEAD

DRAFTING NOTES: (1) Verify frame dimensions. (2) Verify girt dimensions can use 1 1/2".

CORNER COLUMN TO WALL GIRT

D26