1-4.Flange Brace XSST-1 Tabs
NOTE: · Field bend flange brace into place to align with holes in purlins/girts, as required. · Fill all holes in the flange brace with bolts. · If flange brace connection occurs within the purlin lap, install flange brace before tightening purlin bolts. · Flange brace may be one side only. For location and number of sides refer to Cross Sections, Endwall and Sidewall drawings.
BRACE DISTANCE
(3) 1/2" X 1 1/4" BOLTS RAFTER/COLUMN PURLIN/GIRT
FLANGE BRACE TAB (XSST-1)
FLANGE BRACE (FB-x)
1/2" X 1 1/4" BOLTS (1/2" x 1 3/4" BOLTS AT 5/8" THICK FLANGE)
FLANGE BRACE "1-4 CONNECTION"