CS Roof Panel
Common details and conditions related to the CS panel when used in a roof application.
CS Roof Panel Sections & Details
All details downloadable in .dwg and .pdf
Table of Contents
CS Roof - Eave CS Eave Low Side Gutter CS Eave Low Side Gutter No Wall Panel CS Eave Low Side Gutter Oversize CS Eave Low Side Gutter Oversize No Wall Panel CS Eave Low Side Eave Trim CS Eave High Side Eave Trim 2 to 12 and Below
CS Eave Low Side Trim Cap CS Eave High Side Trim Cap CS Eave High Side Trim Cap Over 2 to 12 CS Roof - Gable CS Gable CS Gable Special Trim CS Gable Roof Panel Outside Building Line CS Roof - Height Change CS Gable Height Change to Taller Building CS High Side Height Change w Eave Strut to Taller Building CS High Side Height Change w Zee to Taller Building and Panels Below CS High Side Height Change w Zee to Taller Building CS Inset Gable Height Change to Taller Building and Panels Below CS Outset Gable Height Change to Taller Building and Panels Below CS Roof - Existing Building CS Gable Height Change to Taller Existing Building CS Gable Lap onto Existing Building w CS Roof Panel CS High Side Height Change w Eave Strut to Taller Existing Building CS High Side Height Change w Zee to Taller Existing Building CS High Side Lap Existing CS Roof CS Roof - Panel Details CS Gable and Gutter
CS Gable and Eave Trim CS Gable and Trim Cap CS Gable Roof Cap CS Intermediate purlin NonUL90 CS Intermediate purlin UL90 SCREW_205.CS Panel Splice
CS Roof - Eave
CS Roof Eave
CS Eave Low Side Gutter
EAVE GUTTER (EGA) 1/4-14 X 7/8" WT (6" C.C.) (1) 1/4-14 X 7/8" (TRIM COLOR) GUTTER STRAP (GS) (_____ C.C.) * INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM
1
BL
INSIDE CLOSURE
8 11
(2) 1/4-14 X 7/8" WT
16 "
CS ROOF PANEL
4"
(2) 1/4-14 X 1 1/4" WT (1 EACH SIDE OF HI-RIB)
1/4-14 X 7/8" (12" C.C.)
1/4-14 X 1 1/4" WT(6" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
**
WALL PANEL EAVE STRUT TRIM CAP (TC) INSIDE CLOSURE
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM. * SEE ISOMETRIC DETAIL FOR INSTALLATION OF PIGTAIL MASTIC.
CS Eave Low Side Gutter No Wall Panel
(1) 1/4-14 X 7/8" (TRIM COLOR) GUTTER STRAP (GS) (_____ C.C.) * INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM
1
BL
INSIDE CLOSURE
(2) 1/4-14 X 7/8" WT
8 11 16 "
CS ROOF PANEL
4"
1/4-14 X 7/8" WT (6" C.C.)
(2) 1/4-14 X 1 1/4" WT (1 EACH SIDE OF HI-RIB)
EAVE GUTTER (EGA)
EAVE STRUT 1/4-14 X 1 1/4" WT(6" C.C.)
**
SPECIAL TRIM (SPT- )
#12-14 X 1 1/4" (12" C.C.)
* SEE ISOMETRIC DETAIL FOR INSTALLATION OF PIGTAIL MASTIC. DRAFTING NOTES: ** TRIM CAP TO COVER WEB DEPTH.
CS Eave Low Side Gutter Oversize
(1) 1/4-14 X 7/8" (TRIM COLOR) SPECIAL GUTTER STRAP (SPT- ) (1'-0" C.C.) * INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM
1
INSIDE CLOSURE
BL
(2) 1/4-14 X 7/8" WT
4" 8 11 16 "
CS ROOF PANEL
(2) 1/4-14 X 1 1/4" WT (1) EACH SIDE OF HI-RIB)
1/4-14 X 7/8" WT (6" C.C.)
1/4-14 X 1 1/4" WT (6" C.C.)
SPECIAL EAVE GUTTER (SPT- )
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1/4-14 X 7/8" (12" C.C.)
** INSIDE CLOSURE
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM. * SEE ISOMETRIC DETAIL FOR INSTALLATION OF PIGTAIL MASTIC.
WALL PANEL EAVE STRUT TRIM CAP (TC)
CS Eave Low Side Gutter Oversize No Wall Panel
(1) 1/4-14 X 7/8" (TRIM COLOR) SPECIAL GUTTER STRAP (SPT- ) (1'-0" C.C.) * INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM
1
INSIDE CLOSURE
BL
8 11
(2) 1/4-14 X 7/8" WT
16 "
CS ROOF PANEL
4"
(2) 1/4-14 X 1 1/4" WT (1) EACH SIDE OF HI-RIB)
1/4-14 X 7/8" WT (6" C.C.)
1/4-14 X 1 1/4" WT (6" C.C.)
SPECIAL EAVE GUTTER (SPT- )
1/4-14 X 7/8" (12" C.C.)
**
SPECIAL TRIM (SPT- ) #12-14 X 1 1/4" (12" C.C.)
* SEE ISOMETRIC DETAIL FOR INSTALLATION OF PIGTAIL MASTIC. DRAFTING NOTES: ** TRIM CAP TO COVER WEB DEPTH.
CS Eave Low Side Eave Trim
1
L B
CS ROOF PANEL INSIDE CLOSURE
6"
TRIM CAP (TC) 1/4-14 X 7/8" (12" C.C.) EAVE TRIM (ETA) 1/4-14 X 7/8" WT (12" C.C.) * INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM INSIDE CLOSURE
***
1/4-14 X 1 1/4" WT (6" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
**
EAVE STRUT
1/4-14 X 7/8" (12" C.C.)
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM. * SEE ISOMETRIC DETAIL FOR INSTALLATION OF PIGTAIL MASTIC. NOTE: THE OUTSIDE FACE OF THE EAVE TRIM SHOULD BE PERPENDICULAR TO THE BOTTOM OF THE ROOF PANEL.
OUTSIDE CLOSURE
WALL PANEL
*** TOP OF TRIM PITCH DIMENSION 1:12 0'-1 7/16" 2:12 0'-1" 3:12 0'-1/2" 4:12 0'-0"
CS Eave High Side Eave Trim 2 to 12 and Below
CS ROOF PANEL
1
1/4-14 X 7/8" WT (12" C.C.)
TAPE MASTIC ON TOP OF CLOSURE
CS ROOF PANEL INSIDE CLOSURE 1/4-14 X 7/8" WT (12" C.C.)
HIGHSIDE EAVE TRIM (HSEC)
BL
1 1
HI-SIDE EAVE TRIM (HSEC) * OUTSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM
1/4-14 X 1 1/4" WT (6" C.C.)
2 "
TAPE MASTIC AT PANEL LAP
1/4-14 X 1 1/4" WT (6" C.C.)
1/4-14 X 7/8" (12" C.C.)
WALL PANEL
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
CS INSIDE CLOSURE
TRIM CAP (TCH) INSIDE CLOSURE
CS OUTSIDE CLOSURE
**
1/4-14 X 7/8" (12" C.C.)
EAVE STRUT
TAPE MASTIC ON BOTTOM OF CLOSURE
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
OUTSIDE CLOSURE
WALL PANEL
PIGTAIL TAPE MASTIC (Install a "Pig Tail" down the bearing leg of panel to form a continuous line of tape mastic with panel lap and closure.)
EAVE MEMBER
* See isometric detail "PIGTAIL TAPE MASTIC INSTALLATION WITH HIGH SIDE EAVE TRIM".
TRIM CAP (TCH)
PIGTAIL TAPE MASTIC INSTALLATION WITH HIGH SIDE EAVE TRIM ≤ 2:12
CS Eave Low Side Trim Cap
* INSIDE CLOSURE w/ MASTIC TOP & BOTTOM
1
BL
6"
CS ROOF PANEL
1/4-14 X 1 1/4" WT (6" C.C.)
1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
**
WALL PANEL TRIM CAP (TC) INSIDE CLOSURE
EAVE STRUT
* SEE ISOMETRIC DETAIL FOR INSTALLATION OF PIGTAIL MASTIC.
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
CS Eave High Side Trim Cap
1/4-14 X 1 1/4" WT (6" C.C.)
1
BL
INSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM
4"
TAPE MASTIC AT PANEL LAP
CS ROOF PANEL
PIGTAIL TAPE MASTIC (Install a "Pig Tail" down the bearing leg of panel to form a continuous line of tape mastic with panel lap and closure.)
1/4-14 X 1 1/4" WT (6" C.C.)
1/4-14 X 7/8" (12" C.C.)
WALL PANEL
TAPE MASTIC ON TOP OF CLOSURE
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
TRIM CAP (TCH) * INSIDE CLOSURE
TRIM CAP (TC)
WALL PANEL
EAVE STRUT
* DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
CS INSIDE CLOSURE
EAVE MEMBER
TAPE MASTIC ON BOTTOM OF CLOSURE
HIGH SIDE TRIM CAP ONLY
CS Eave High Side Trim Cap Over 2 to 12
CS ROOF PANEL
1
1/4-14 X 7/8" WT (12" C.C.)
TAPE MASTIC ON TOP OF CLOSURE
HIGHSIDE EAVE TRIM (HSEC)
BL
CS OUTSIDE CLOSURE
INSIDE CLOSURE 1/4-14 X 7/8" WT (12" C.C.)
TRIM CAP (TCH) 1/4-14 X 7/8" (12" C.C.) * OUTSIDE CLOSURE w/ TAPE MASTIC TOP AND BOTTOM
1 1
2 "
1/4-14 X 1 1/4" WT (6" C.C.)
TAPE MASTIC AT PANEL LAP
CS ROOF PANEL
**
INSIDE CLOSURE
WALL PANEL
HIGH SIDE EAVE TRIM (HSEC)
CS INSIDE CLOSURE
1/4-14 X 1 1/4" WT (6" C.C.)
OUTSIDE CLOSURE 1/4-14 X 7/8" (12" C.C.) 1/4-14 X 7/8" (12" C.C.) EAVE CLOSURE TRIM (ECT)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
TAPE MASTIC ON BOTTOM OF CLOSURE
EAVE CLOSURE TRIM (ECT)
EAVE STRUT
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
PIGTAIL TAPE MASTIC (Install a "Pig Tail" down the bearing leg of panel to form a continuous line of tape mastic with panel lap and closure.)
WALL PANEL
EAVE MEMBER
* See isometric detail "PIGTAIL TAPE MASTIC INSTALLATION WITH HIGH SIDE EAVE TRIM > 2:12".
TRIM CAP (TCH)
PIGTAIL TAPE MASTIC INSTALLATION WITH HIGH SIDE EAVE TRIM >2:12
CS Roof - Gable
CS Roof Gable
CS Gable
1
1/4-14 X 1 1/4" WT (12" C.C.)
BL
GABLE TRIM (GTC) RAKE ANGLE (A-20)
DOUBLE BEAD TAPE MASTIC CS ROOF PANEL
2 1/8"
1"
**
INSIDE CLOSURE
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
WALL PANEL 1/4-14 X 7/8" (12" C.C.) *OUTSIDE CLOSURE
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) PURLIN
* NOTE: Field cut outside closure for higher roof pitches.
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
CS Gable Special Trim
1
1/4-14 X 1 1/4" WT (12" C.C.)
BL
GABLE TRIM (SPT- ) RAKE ANGLE (A-20-H)
X"
DOUBLE BEAD TAPE MASTIC CS ROOF PANEL
X"
1"
INSIDE CLOSURE
**
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) PURLIN
*OUTSIDE CLOSURE
WALL PANEL
*NOTE: Field cut outside closure for higher roof pitches.
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
CS Gable Roof Panel Outside Building Line
1
1/4-14 X 1 1/4" WT (12" C.C.) DOUBLE BEAD TAPE MASTIC CS ROOF PANEL
BL
RAKE ANGLE (A-20) GABLE TRIM (GTC)
2 1/8"
X"
1"
**
INSIDE CLOSURE
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
1/4-14 X 7/8" (12" C.C.)
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) PURLIN
*OUTSIDE CLOSURE
*NOTE: Field cut outside closure for higher roof pitches.
WALL PANEL
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
CS Roof - Height Change
CS Roof Height Change
CS Gable Height Change to Taller Building
*WALL PANEL
HEIGHT CHANGE ANGLE (A-20-H)
BL
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
DOUBLE BEAD TAPE MASTIC CS ROOF PANEL 1/4-14 X 1 1/4" WT (12" C.C.) HEIGHT CHANGE TRIM (RHT) INSIDE CLOSURE
1
4 "
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) PURLIN
1"
* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
CS High Side Height Change w Eave Strut to Taller Building
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) GIRT WALL PANEL
1
BL
OUTSIDE CLOSURE (2" X 3') 1/4-14 X 7/8" WT (12" C.C.) HEIGHT CHANGE TRIM (LHTC) INSIDE CLOSURE
1 4 " Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1 1 2 "
CS ROOF PANEL
1/4-14 X 1 1/4" WT (6" C.C.) EAVE STRUT 2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLOSURE
CS High Side Height Change w Zee to Taller Building and Panels Below
INSIDE CLOSURE #12-14 X 1 1/4" (TYP.) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B) WALL PANEL (TYP.)
1
BL
1 1 2 "
1/4-14 X 7/8" WT (12" C.C.) HEIGHT CHANGE TRIM (LHTC) (2) #12-14 X 1 1/4" (GA) ( 36" C.C.)
Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1
4 "
OUTSIDE CLOSURE (2" X 3')
CS ROOF PANEL 1/4-14 X 1 1/4" WT (6" C.C.) PURLIN
GIRT
2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLOSURE
1/4-14 X 7/8" (12" C.C.) PANELING CAP TRIM (SCT)
9"
CS High Side Height Change w Zee to Taller Building
WALL PANEL
1
GIRT
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
BL
1/4-14 X 7/8" WT (12" C.C.) HEIGHT CHANGE TRIM (LHTC) INSIDE CLOSURE
OUTSIDE CLOSURE (2" X 3')
1 4 " Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.
1 1 2 "
CS ROOF PANEL 1/4-14 X 1 1/4" WT (6" C.C.) PURLIN
9"
2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLOSURE
CS Inset Gable Height Change to Taller Building and Panels Below
HEIGHT CHANGE TRIM (RHT) INSIDE CLOSURE
HEIGHT CHANGE ANGLE (A-20-H) *WALL PANEL (TYP.)
BL
1/4-14 X 1 1/4" WT (12" C.C.)
#12-14 X 1 1/4"(TYP.) (CS - 6" C.C.)(AP - 12" C.C.)
DOUBLE BEAD TAPE MASTIC CS ROOF PANEL
1
4 "
PURLIN
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) HEIGHT CHANGE RAFTER
1"
RAKE ANGLE (A-20)
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)
* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
(2) #12-24 X 1 1/2" AT 36" C.C.
PANELING CAP TRIM (SCT) 1/4-14 X 7/8" (12" C.C.)
CS Outset Gable Height Change to Taller Building and Panels Below
HEIGHT CHANGE TRIM (RHT) INSIDE CLOSURE
#12-14 X 1 1/4" (TYP.) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) HEIGHT CHANGE ANGLE (A-20-H) *WALL PANEL (TYP.)
BL
1/4-14 X 1 1/4" WT (12" C.C.)
DOUBLE BEAD TAPE MASTIC CS ROOF PANEL
1
4 "
PURLIN
PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)
1"
HEIGHT CHANGE RAFTER
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR)
#12-14 X 1 1/4" (GA) (2 EACH PURLIN)
RAKE ANGLE (A-20) PANELING CAP TRIM (SCT) 1/4-14 X 7/8" (12" C.C.)
* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
CS Roof - Existing Building
CS Roof Existing Building
CS Gable Height Change to Taller Existing Building
1
SEALANT (NOT BY CHIEF) FASTENER AT 12" C.C. (NOT BY CHIEF) COUNTER FLASHING (NOT BY CHIEF)
L EXISTING B
SPECIAL TRIM (SPT- )
DOUBLE BEAD TAPE MASTIC CS ROOF PANEL 1/4-14 X 1 1/4" WT (12" C.C.)
1"
#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) PURLIN RAKE ANGLE (A-20)
3"
CS Gable Lap onto Existing Building w CS Roof Panel
1
EXISTING CS ROOF PANEL TAPE MASTIC 1/4-14 X 7/8" WT (12" C.C.)
1'-0" L EXISTING B
NEW CS ROOF PANEL
NOTE: Remove existing gable trim, apply tape mastic, lap new panel over existing panel and fasten with 1/4-14 X 7/8" WT fasteners 12" C.C.
PURLIN
3"
CS High Side Height Change w Eave Strut to Taller Existing Building
1
FASTENER AT 12" C.C. (NOT BY CHIEF) COUNTER FLASHING (NOT BY CHIEF)
L EXISTING B
1/4-14 X 7/8" WT (12" C.C.) HEIGHT CHANGE TRIM (LHTC) SEALANT (NOT BY CHIEF)
OUTSIDE CLOSURE (2" X 3')
1 1
2 "
CS ROOF PANEL
2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLOSURE
1/4-14 X 1 1/4" WT ( 6" C.C.) EAVE STRUT
CS High Side Height Change w Zee to Taller Existing Building
1
FASTENER AT 12" C.C. (NOT BY CHIEF) COUNTER FLASHING (NOT BY CHIEF)
L EXISTING B
1/4-14 X 7/8" WT (12" C.C.) HEIGHT CHANGE TRIM (LHTC) SEALANT (NOT BY CHIEF)
OUTSIDE CLOSURE (2" X 3')
1 1 2 "
9"
CS ROOF PANEL 1/4-14 X 1 1/4" WT (6" C.C.) PURLIN
2 ROWS DOUBLE BEAD MASTIC TOP & BOTTOM OF OUTSIDE CLOSURE
CS High Side Lap Existing CS Roof
* EXISTING FASTENER AT EAVE
BL
CS ROOF PANEL 1/4-14 X 1 1/4" WT(6" C.C.) (TYP) TAPE MASTIC (TYP)
EXISTING CS ROOF PANEL
4"
EXISTING WALL PANEL EXISTING EAVE STRUT EXISTING TRIM CAP
3"
* DO NOT REMOVE FASTENER AT EAVE
EAVE STRUT
CS Roof - Panel Details
CS Roof Panel Details
CS Gable and Gutter
4 2 6
CS ROOF PANEL - The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.
5
1/4-14 X 7/8" WT (1-1/2" C.C.)
ROOF JACK
1
1/4-14 X 1 1/4" WT (6" C.C.) (TYP.)
CS ROOF PANEL
3
1/4-14 X 7/8" (18" C.C.) (TYP.)
TAPE MASTIC AT PANEL LAP
1/4-14 X 1 1/4" WT (6" C.C.)
CS ROOF PANEL
FASTENER ORDER
3" (TYP.)
PIGTAIL TAPE MASTIC (Install a "Pig Tail" down the bearing leg of panel to form a continuous line of tape mastic with panel lap and closure.)
PANEL TO EAVE STRUT
1/4-14 X 7/8" WT (6" C.C.)
1"
CS INSIDE CLOSURE
1/4-14 X 7/8" WT (12" C.C. FOR FIRST 6' FROM EAVE, REMAINDER AT 18" C.C.)
TAPE MASTIC ON TOP OF CLOSURE
TAPE MASTIC
WALL PANEL
OVERLAPPING ROOF PANEL
UNDER-LAPPING ROOF PANEL
DOUBLE BEAD TAPE MASTIC UNDERSIDE OF ROOF JACK PIPE FLASHING FLANGE
EAVE GUTTER
PURLIN
TAPE MASTIC ON BOTTOM OF CLOSURE
EAVE MEMBER
Roof Jack Installation when Supplied By Chief 1. Cut a neat hole in roof panel with minimum clearance for pipe and install pipe. 2. Cut pliable Roof Jack using sharp pair of scissors, avoiding nicks. Hole should be 1/2" to 2" smaller than diameter of pipe to be flashed. 3. Drill 3/16" diameter holes at approximately 1-1/2" C.C. around base of Roof Jack. 4. Apply Double Bead Tape Mastic to underside of Roof Jack. Then using water as a lubricant, slide it onto the pipe until it meets panel. 5. Press Roof Jack base into contours of panel. A blunt tool can be used to press flanges into place at sharp angles. 6. Begin fastening Roof Jack progressively to roof panel with 1/4-14x7/8" WT at opposite sides, using predrilled holes as a template. 7. Install Stainless Steel Clamp around top of Roof Jack to secure it to the pipe (Not By Chief). General Notes: · In Northern Climates, the pipe penetration should be protected from moving ice or snow with a snow retention system (Not By Chief). Roof Jacks Not Supplied By Chief · Do Not Use Galvanized Roof Jacks, Lead Hats, or other residential grade Roof Jacks. These Roof Jacks do not have a 20 year service life and in case of Lead Hats will cause Galvanic Corrosion of the roof panel. · Use EPDM rubber Roof Jacks with an integral aluminum band bonded into the perimeter of the base. EPDM Roof Jacks have a temperature range from -65°F to 212°F. Use Silicon Roof Jacks for high temperatures. Silicone Roof Jacks have a temperature range of -100°F to 437°F. · Do not use Tube Sealant to seal the Roof Jack to the panels. Use roll tape sealer (Not By Chief) between the Roof Jack and the roof panel and attach the Roof Jack to the roof panel with 1/4-14x7/8 long life fasteners (Not By Chief) 1-1/2" C.C. around the base of the Roof Jack.
UNDER-LAPPING ROOF PANEL PURLIN BEARING LEG
CS INSIDE CLOSURE
TRIM CAP (TC)
PIGTAIL TAPE MASTIC INSTALLATION WITH EAVE GUTTER
PANEL SIDELAP
UPPER SLOPE GABLE TRIM
GABLE TRIM
(20) 1/8" X 3/8" BLIND RIVETS
LOWER SLOPE GABLE TRIM
GABLE TRIM PLUG
CS ROOF PANEL
B L
2" LAP
3"
2" LAP
EAVE GUTTER
TRIM CAP
NOTES: · Use 2" lap at splices and field cut 3/8" Lockform at splice. · Fasten splice with (12) 1/8" x 3/8" blind rivets. · Sealant at splice not shown. All sealant used is 511-SIKALASTOMER at gable trim, gable ridge trim, gable corner trim gutter, trim cap, eave trim and height change trim splices and trim plugs.
(2) 1/8" X 3/8" BLIND RIVETS
GABLE CORNER TRIM
NOTE: · For roof overhang see additional sections. · Start gable trim 5 3/4" out from end of roof panel. · Start eave gutter 3" out from endwall building line. · Sealant at plug and corner trim not shown.
NOTES: · Use 2" lap at splices and field cut 3/8" Lockform at splice. · 511-SIKALASTOMER sealant at splice not shown.
GABLE TRIM SPLICE
GABLE CORNER TRIM WITH EAVE GUTTER
TRIM CAP SPLICE
ROOF JACK PIPE FLASHING WITH CS ROOF
CS Gable and Eave Trim
4 2 6
CS ROOF PANEL - The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.
5
1/4-14 X 7/8" WT (1-1/2" C.C.)
ROOF JACK
1
CS ROOF PANEL
1/4-14 X 1 1/4" WT (6" C.C.) (TYP.)
3
1/4-14 X 7/8" (18" C.C.) (TYP.)
TAPE MASTIC AT PANEL LAP
1/4-14 X 1 1/4" WT (6" C.C.)
CS ROOF PANEL
FASTENER ORDER
3" (TYP.)
PIGTAIL TAPE MASTIC (Install a "Pig Tail" down the bearing leg of panel to form a continuous line of tape mastic with panel lap and closure.)
PANEL TO EAVE STRUT
1/4-14 X 7/8" WT (12" C.C.)
CS INSIDE CLOSURE
1/4-14 X 7/8" WT (12" C.C. FOR FIRST 6' FROM EAVE, REMAINDER AT 18" C.C.)
2"
TAPE MASTIC ON TOP OF CLOSURE
TAPE MASTIC
WALL PANEL
OVERLAPPING ROOF PANEL
UNDER-LAPPING ROOF PANEL
DOUBLE BEAD TAPE MASTIC UNDERSIDE OF ROOF JACK PIPE FLASHING FLANGE
EAVE TRIM (ETA)
PURLIN
TAPE MASTIC ON BOTTOM OF CLOSURE
Roof Jack Installation when Supplied By Chief 1. Cut a neat hole in roof panel with minimum clearance for pipe and install pipe. 2. Cut pliable Roof Jack using sharp pair of scissors, avoiding nicks. Hole should be 1/2" to 2" smaller than diameter of pipe to be flashed. 3. Drill 3/16" diameter holes at approximately 1-1/2" C.C. around base of Roof Jack. 4. Apply Double Bead Tape Mastic to underside of Roof Jack. Then using water as a lubricant, slide it onto the pipe until it meets panel. 5. Press Roof Jack base into contours of panel. A blunt tool can be used to press flanges into place at sharp angles. 6. Begin fastening Roof Jack progressively to roof panel with 1/4-14x7/8" WT at opposite sides, using predrilled holes as a template. 7. Install Stainless Steel Clamp around top of Roof Jack to secure it to the pipe (Not By Chief). General Notes: · In Northern Climates, the pipe penetration should be protected from moving ice or snow with a snow retention system (Not By Chief). Roof Jacks Not Supplied By Chief · Do Not Use Galvanized Roof Jacks, Lead Hats, or other residential grade Roof Jacks. These Roof Jacks do not have a 20 year service life and in case of Lead Hats will cause Galvanic Corrosion of the roof panel. · Use EPDM rubber Roof Jacks with an integral aluminum band bonded into the perimeter of the base. EPDM Roof Jacks have a temperature range from -65°F to 212°F. Use Silicon Roof Jacks for high temperatures. Silicone Roof Jacks have a temperature range of -100°F to 437°F. · Do not use Tube Sealant to seal the Roof Jack to the panels. Use roll tape sealer (Not By Chief) between the Roof Jack and the roof panel and attach the Roof Jack to the roof panel with 1/4-14x7/8 long life fasteners (Not By Chief) 1-1/2" C.C. around the base of the Roof Jack.
EAVE MEMBER
UNDER-LAPPING ROOF PANEL PURLIN BEARING LEG
TRIM CAP (TC)
CS INSIDE CLOSURE
PIGTAIL TAPE MASTIC INSTALLATION WITH EAVE TRIM
PANEL SIDELAP
2" LAP
UPPER SLOPE GABLE TRIM
GABLE TRIM
EAVE TRIM
LOWER SLOPE GABLE TRIM
(19) 1/8" X 3/8" BLIND RIVETS
GABLE TRIM PLUG
CS ROOF PANEL
(9) 1/8" X 3/8" BLIND RIVETS
B L
2" LAP
3"
EAVE TRIM
2" LAP
NOTES: · Use 2" lap at splices and field cut 3/8" Lockform at splice. · Fasten splice with (12) 1/8" x 3/8" blind rivets. · Sealant at splice not shown. All sealant used is 511-SIKALASTOMER at gable trim, gable ridge trim, gable corner trim gutter, trim cap, eave trim and height change trim splices and trim plugs.
TRIM CAP
GABLE CORNER TRIM
(2) 1/8" X 3/8" BLIND RIVETS
NOTE: · For roof overhang see additional sections. · Start gable trim bottom leg 4" past building line. · Start eave trim 3" out from building line. · Field cut roof sheet at gable corner trim. · Sealant at plug and corner trim not shown.
NOTES: · Use 2" lap at splices and field cut 3/8" Lockform at splice. · 511-SIKALASTOMER sealant at splice not shown.
GABLE TRIM SPLICE
GABLE CORNER TRIM WITH EAVE TRIM
EAVE TRIM & TRIM CAP SPLICE
ROOF JACK PIPE FLASHING WITH CS ROOF
CS Gable and Trim Cap
4 2 6
The details shown below are typical Chief metal building details. Not all details may apply. Specific details for additional features will be provided for complete installation instructions.
5
1/4-14 X 7/8" WT (1-1/2" C.C.)
ROOF JACK
1
1/4-14 X 1 1/4" WT (6" C.C.) (TYP.)
CS ROOF PANEL
3
1/4-14 X 7/8" (18" C.C.) (TYP.)
TAPE MASTIC AT PANEL LAP
1/4-14 X 1 1/4" WT (6" C.C.)
CS ROOF PANEL
FASTENER ORDER
3" (TYP.)
PIGTAIL TAPE MASTIC (Install a "Pig Tail" down the bearing leg of panel to form a continuous line of tape mastic with panel lap and closure.) TAPE MASTIC ON TOP OF CLOSURE
PANEL TO EAVE STRUT
6 1/2"
1/4-14 X 7/8" WT (12" C.C. FOR FIRST 6' FROM EAVE, REMAINDER AT 18" C.C.)
TAPE MASTIC
WALL PANEL
OVERLAPPING ROOF PANEL
UNDER-LAPPING ROOF PANEL
DOUBLE BEAD TAPE MASTIC UNDERSIDE OF ROOF JACK PIPE FLASHING FLANGE
TRIM CAP (TC)
PURLIN
TAPE MASTIC ON BOTTOM OF CLOSURE
EAVE MEMBER
Roof Jack Installation when Supplied By Chief 1. Cut a neat hole in roof panel with minimum clearance for pipe and install pipe. 2. Cut pliable Roof Jack using sharp pair of scissors, avoiding nicks. Hole should be 1/2" to 2" smaller than diameter of pipe to be flashed. 3. Drill 3/16" diameter holes at approximately 1-1/2" C.C. around base of Roof Jack. 4. Apply Double Bead Tape Mastic to underside of Roof Jack. Then using water as a lubricant, slide it onto the pipe until it meets panel. 5. Press Roof Jack base into contours of panel. A blunt tool can be used to press flanges into place at sharp angles. 6. Begin fastening Roof Jack progressively to roof panel with 1/4-14x7/8" WT at opposite sides, using predrilled holes as a template. 7. Install Stainless Steel Clamp around top of Roof Jack to secure it to the pipe (Not By Chief). General Notes: · In Northern Climates, the pipe penetration should be protected from moving ice or snow with a snow retention system (Not By Chief). Roof Jacks Not Supplied By Chief · Do Not Use Galvanized Roof Jacks, Lead Hats, or other residential grade Roof Jacks. These Roof Jacks do not have a 20 year service life and in case of Lead Hats will cause Galvanic Corrosion of the roof panel. · Use EPDM rubber Roof Jacks with an integral aluminum band bonded into the perimeter of the base. EPDM Roof Jacks have a temperature range from -65°F to 212°F. Use Silicon Roof Jacks for high temperatures. Silicone Roof Jacks have a temperature range of -100°F to 437°F. · Do not use Tube Sealant to seal the Roof Jack to the panels. Use roll tape sealer (Not By Chief) between the Roof Jack and the roof panel and attach the Roof Jack to the roof panel with 1/4-14x7/8 long life fasteners (Not By Chief) 1-1/2" C.C. around the base of the Roof Jack.
UNDER-LAPPING ROOF PANEL PURLIN BEARING LEG
CS INSIDE CLOSURE
PIGTAIL TAPE MASTIC INSTALLATION WITH TRIM CAP ONLY
PANEL SIDELAP
UPPER SLOPE GABLE TRIM
SEALANT AT SPLICE NOT SHOWN
GABLE TRIM
(15) 1/8" X 3/8" BLIND RIVETS
LOWER SLOPE GABLE TRIM
GABLE TRIM PLUG
2" LAP
2" LAP
TRIM CAP
CS ROOF PANEL
TRIM CAP
NOTES: · Use 2" lap at splices and field cut 3/8" Lockform at splice. · Fasten splice with (12) 1/8" x 3/8" blind rivets. All sealant used is 511-SIKALASTOMER at gable trim, gable ridge trim, gable corner trim gutter, trim cap, eave trim and height change trim splices and trim plugs.
(2) 1/8" X 3/8" BLIND RIVETS
GABLE CORNER TRIM
NOTE: · For roof overhang see additional sections. · Start Gable Trim even with end of roof panel. · Locate gable trim plug against hi-rib of endwall panel. · Sealant at plug and corner trim not shown.
NOTES: · Use 2" lap at splices and field cut 3/8" Lockform at splice. · 511-SIKALASTOMER sealant at splice not shown.
GABLE TRIM SPLICE
GABLE CORNER TRIM AT TRIM CAP ONLY
TRIM CAP SPLICE
ROOF JACK PIPE FLASHING WITH CS ROOF
CS Gable Roof Cap
CS ROOF PANEL
TAPE MASTIC AT PANEL SIDE LAPS
CS ROOF CAP
TAPE MASTIC AT PANEL SIDE LAPS BETWEEN PANEL ROWS (TYP).
(3)1/4-14 X 1 1/4" WT (PER FOOT)
DOUBLE BEAD TAPE MASTIC
TAPE MASTIC AT ROOF CAP TO ROOF PANEL END LAP
2" (TRIM LAP)
RAKE ANGLE (A-20)
PURLIN
WALL PANEL
1/4-14 X 1 1/4" WT (12" C.C.)
CS ROOF PANEL
GABLE RIDGE TRIM
1/4-14 X 1 1/4" WT (12" C.C.)
1/4-14 X 7/8" (12" C.C.)
2" (TRIM LAP)
GABLE TRIM
(12) 1/8" X 3/8" BLIND RIVETS
1/4-14 X 7/8" (12" C.C.)
TAPE MASTIC AT PANEL SIDE LAPS
1/4-14 X 7/8" WT (12" C.C.)
TAPE MASTIC AT PANEL SIDE LAPS
(3)1/4-14 X 1 1/4" WT (PER FOOT)
ROOF PANEL
NOTES: · Use 2" lap at splices and field cut 3/8" Lockform at splice. · Fasten splice with (12) 1/8" x 3/8" blind rivets. · Sealant at splice not shown. All sealant used is 511-SIKALASTOMER at gable trim, gable ridge trim, gable corner trim gutter, trim cap, eave trim and height change trim splices and trim plugs.
ROOF CAP
TAPE MASTIC AT PANEL SIDE LAPS BETWEEN PANEL ROWS
TAPE MASTIC AT ROOF CAP TO ROOF PANEL END LAPS
5" (MIN.)
5" (MIN.) 7"
7"
PURLIN
1"
1"
CS ROOF PANEL RIDGE DETAIL
CS Intermediate purlin NonUL90
1'-0"
1'-0"
1'-0"
3"
3"
TAPE MASTIC AT PANEL SIDE LAPS
1/4-14 X 1 1/4" WT (12" C.C.)
CS ROOF PANEL
PURLIN
FASTENER SPACING NON-UL-90
CS Intermediate purlin UL90
6"
6"
6"
6"
6"
6"
6"
3" 3"
3" 3"
TAPE MASTIC AT PANEL SIDE LAPS
1/4-14 X 1 1/4" WT (6" C.C.)
CS ROOF PANEL
PURLIN
FASTENER SPACING UL-90
SCREW_205.CS Panel Splice
1/4-14 X 1 1/4" WT (6" C.C.)
TAPE MASTIC AT PANEL SIDE LAPS BETWEEN PANEL ROWS
8"
TAPE MASTIC AT PANEL SIDE LAPS
TAPE MASTIC AT PANEL END LAPS
UPPER CS ROOF PANEL
5"
1" 2"
LOWER CS ROOF PANEL TAPE MASTIC AT PANEL SIDE LAPS
PURLIN
UPPER CS ROOF PANEL
1/4-14 X 1 1/4" WT (6" C.C.)
TAPE MASTIC AT PANEL SIDE LAPS
TAPE MASTIC AT PANEL SIDE LAPS BETWEEN PANEL ROWS.
PURLIN
LOWER CS ROOF PANEL
TAPE MASTIC AT PANEL END LAPS
CS ROOF PANEL ENDLAP PURLIN DETAIL