Eave and Gable Extensions

MVF-MVP Gable Ext Tail End w CS Soffit and Thermal Spacer

* NOTE: This fastener must not hit the purlin.

CLIP LOCATION FROM SL ROOF PANEL CUT BACK DIMENSION

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

GABLE EXTENSION DIMENSION

CLOSURE CLIPS (GCC-1) (TYP.)

PURLIN CLOSURE (TYP.)

PURLIN

BL

#12-14 X 1 1/4" (2 EACH PURLIN) (WALL COLOR) * 1/4-14 X 1 1/4" WT (6" C.C.) DOUBLE BEAD TAPE MASTIC DOUBLE BEAD TAPE MASTIC PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION

GABLE TRIM (GTVC)

PRE-GLUED THERMAL SPACER

(NOT BY CHIEF)

1 3 4 "

MVF/MVP ROOF PANEL PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN) PURLIN CLOSURE (GPC)

GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) (2) 1/4-14 X 7/8" PANEL CLIP w/FASTENERS RAKE ANGLE (A-20-B) (2) #12-14 X 1 1/4"(WALL COLOR) EACH CLIP

1"

PURLIN

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN

(NOT BY CHIEF)

(2) #12-14 X 1 1/4"' PER CLOSURE

TOP VIEW

GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.) GABLE EXPANSION TRIM (GET)

CS SOFFIT PANEL 1/4-14 X 7/8" (12" C.C.) JAMB TRIM (JT) 1/4-14 X 7/8" (12" C.C.) PANEL CAP TRIM (SCT)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

#12-14 X 1" PANCAKE HEAD EACH PURLIN EXTENSION FLASHING (EFC)

EAVE STRUT

INSIDE CLOSURE **

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

RAKE ANGLE (A-20-B) WALL PANEL

#12-14 X 1 1/4" (12" C.C.)

** DRAFTING NOTE: Inside closure must be provided on buildings with Liner Insulation System.

PURLIN CLOSURE INSTALLATION