Eave and Gable Extensions

LS Eave Ext Only - Horiz FSP Soffit Inset Gable and CS Roof Panel High Pitch

REFER TO GABLE SECTIONS FOR ROOF PANEL AND GABLE TRIM ATTACHMENTS AT THE BUILDING GABLE. *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

NOTE: * PRE-DRILL TOP AND BOTTOM FLANGE OF EXTENSION BEAM FOR FASTENERS Provide air gap of 1/4" min. at bottom of panel to avoid corrosion.

1

SPECIAL CHANNEL (PL- )

* (2) #12-14 X 1 1/4" (WALL COLOR) (TYP.) EAVE EXTENSION BEAM * #12-14 X 1 1/4" (WALL COLOR) (AT PURLIN)

INSIDE CLOSURE

BL

***

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

1"

INTERMEDIATE PURLIN

EAVE EXTENSION END PANEL

#12-14 X 1" PANCAKE HEAD (24" C.C.)

SOFFIT RAKE ANGLE (A-20-H)

INSIDE CLOSURE **

#12-14 X 1" PANCAKE HEAD

SOFFIT TRIM (VPST)

XXX' - X"

#12-14 X 1 1/4" GIRT ANGLE (XGA- )

1

4 "

PANEL SUPPORT (SSSP)

SOFFIT PURLIN

1/8" X 3/8" BLIND RIVET (12" C.C.)

FSP SOFFIT PANEL

**DRAFTING: INSIDE CLOSURE NOT REQ'D IF WALLS ARE "CS INSULATED"

#12-14 X 1" PANCAKE HEAD (12" C.C.) (TYP.)

Made with FlippingBook flipbook maker