Eave and Gable Extensions
STC-MSC Low Side Eave Ext w Eave Trim and CS-AP Soffit and Thermal Spacer
PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION (NOT BY CHIEF) PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)
1/4-14 X 1 1/4" WT (8 PER PANEL)
BL
METAL INSIDE CLOSURE TRI-BEAD TAPE MASTIC (TOP AND BOTTOM) 2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS
STC/MSC ROOF PANEL
2 "
5 1
* TRAPEZOID PLUG (TRP) AT EACH HIGH RIB
1/4-14 X 1 1/4" WT (6 PER PANEL)
1/4-14 X 7/8" WT (5 PER PANEL)
INTERMED. PURLIN ***
DOUBLE BEAD TAPE MASTIC (TOP AND BOTTOM)
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
EAVE TRIM (ETM)
INSIDE CLOSURE **
1/4-14 X 7/8" (12" C.C.) #12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR) OUTSIDE CLOSURE SOFFIT TRIM (ESTO) 1/4-14 X 7/8" (12" C.C.) WALL PANEL
SOFFIT PANEL 1/4-14 X 1" (2 PER CLOSURE)
EXTENSION FLASHING (EF)
#12-14 X 1 1/4" (12" C.C.)
1/4-14 X 7/8" (12" C.C.) OUTSIDE CLOSURE
* See isometric Trapezoid Plug Installation detail for installation instructions.
DRAFTING NOTES: **
Inside closure must be provided on buildings with liner insulation system. If intermediate purlin is required, chg purlin, t-spacer and all fasteners to "dim" layer.
***
Made with FlippingBook flipbook maker