Eave and Gable Extensions
STC-MSC Low Side Eave Ext w Eave Trim and NO Soffit and Thermal
1/4-14 X 1 1/4" WT (6 PER PANEL) 1/8" X 3/8" BLIND RIVET (PARCHMENT) (2 PER PLUG) TRAPEZOID PLUG (TRP) AT EACH HIGH RIB PRE-GLUED THERMAL SPACER FOR EAVE EXTENSION (NOT BY CHIEF) PANEL CLIP W/ FASTENERS (SEE ROOF PANEL PLAN)
METAL INSIDE CLOSURE TRI-BEAD TAPE MASTIC (TOP AND BOTTOM) STC/MSC ROOF PANEL 2" STRIP OF TRI-BEAD TAPE MASTIC BETWEEN PANELS 1/4-14 X 1 1/4" WT (8 PER PANEL)
BL
* TRAPEZOID PLUG (TRP) AT EACH HIGH RIB
5 1
2 "
1/4-14 X 7/8" WT (5 PER PANEL)
DOUBLE BEAD TAPE MASTIC (TOP AND BOTTOM)
INTERMED. PURLIN ***
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)
EAVE TRIM (ETM) 1/4-14 X 7/8" (12" C.C.)
INSIDE CLOSURE **
1/4-14 X 1" (2 PER CLOSURE)
1/4-14 X 7/8" (12" C.C.)
EXTENSION FLASHING (EF)
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR)
PANEL CAP TRIM (SCT)
DRAFTING NOTES: **
WALL PANEL
Inside closure must be provided on buildings with liner insulation system. If intermediate purlin is required, chg purlin, t-spacer and all fasteners to "dim" layer.
NOTE: Jamb trim around extension beam as required.
***
* See isometric Trapezoid Plug Installation detail for installation instructions.
Made with FlippingBook flipbook maker