Eave and Gable Extensions
STC-MSC Gable Ext Tail End w AP Soffit and Thermal Spacer
* NOTE: It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.
PURLIN
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
GABLE EXTENSION DIMENSION
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
BL
PURLIN CLOSURE (TYP.)
PRE-GLUED THERMAL SPACER FOR GABLE EXTENSION #12-14 X 1" PANCAKE HEAD (2 PER PURLIN) TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.)
PANEL CLIP w/FASTENERS (SEE ROOF PANEL PLAN)
#12-14 X 1 1/4" (12" C.C.) (TRIM COLOR) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) RAKE SUPPORT (A-20-T) GABLE TRIM (GTMC)
PURLIN
STC/MSC ROOF PANEL
PURLIN
(NOT BY CHIEF)
THERMAL SPACER
PURLIN CLOSURE (GPC)
(NOT BY CHIEF)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
#12-14 X 1 1/4" AT EACH PURLIN ROW (WALL COLOR) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) PURLIN CLOSURE CLIP (GCC-1) (FIELD MODIFY CLIP AS REQ'D) (2) 1/8" X 3/8" BLIND RIVETS TO CONNECT EACH CLIP TO EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" TO CONNECT EACH CLIP TO EACH PURLIN
(2) #12-14 X 1 1/4"' PER CLOSURE
(2) 1/4-14 X 7/8"
TOP VIEW
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
#12-14 X 1 1/4" (12" C.C.) (SOFFIT COLOR) EXTENSION FLASHING (EF) PANEL SUPPORT TRIM (SSP) 1/4-14 X 7/8" (12" C.C.) GABLE EXTENSION CHANNEL (GEC) 1/4-14 X 7/8" (12" C.C.) GABLE EXPANSION TRIM (GET)
AP SOFFIT PANEL
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
1/4-14 X 7/8" (12" C.C.) (SOFFIT COLOR)
PANEL SUPPORT TRIM (SSP) 1/4-14 X 7/8" (12" C.C.)
INSIDE CLOSURE **
EAVE STRUT
JAMB TRIM (JT)
PANEL CAP TRIM (SCT) RAKE ANGLE (A-20-B)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
1/4-14 X 7/8" (12" C.C.)
** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
WALL PANEL
#12-14 X 1" PANCAKE HEAD EACH PURLIN
PURLIN CLOSURE INSTALLATION