STC MSC Roof Panel
STC-MSC Eave Isometric w Eave Trim
STC/MSC ROOF PANEL
(4) 1/8" X 3/8" BLIND RIVETS
(22) 1/8" X 3/8" BLIND RIVETS
GABLE TRIM (GTMC)
STC/MSC ROOF PANEL
GABLE TRIM (GTMC)
EAVE TRIM (ETM)
*DOUBLE BEAD TAPE MASTIC
GABLE TRIM PLUG (TPRMC/TPLMC)
*TRAPEZOID PLUG (TRP)
FILL HOLE W/ 1/8" X 3/8" BLIND RIVET (BOTH LEGS)
(13) 1/8" X 3/8" BLIND RIVETS
GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)
2" STRIP OF MINOR RIB TAPE SEALER (TYP.)
GABLE CORNER TRIM (GCTMC)
NOTE: 1. Start gable trim bottom leg 4" out from sidewall building line. Notch gable trim to avoid corner box rivets. 2. Start eave trim 3" out from endwall building line. 3. Locate Gable Trim Plug as close to building line as possible. Field notch as required. 4. Field cut roof panel at gable corner trim. (as required) 5. Use SIKA 511 sealant at plug and gable corner trim to eave trim. GABLE CORNER TRIM WITH EAVE TRIM
GABLE EXPANSION TRIM (GET)
NOTE: 1. Use 2" lap at splices, and field cut 3/8" lockform at splice. 2. Fasten splice with (13) 1/8" x 3/8" blind rivets. 3. Use SIKA 511 sealant at splice.
EAVE TRIM (ETM)
*EDGE OF MASTIC ALIGNS WITH FACE OF TRAPEZOID PLUG
DOUBLE BEAD TAPE MASTIC
GABLE TRIM SPLICE
TRAPEZOID PLUG INSTALLATION WITH EAVE TRIM