STC MSC Roof Panel

MSC 2-Inch-Gable Lead End-Vertical Leg Set Back from Building Line-Term Trim-Thermal Spacer

TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) 1/4-14 X 7/8" WT (6" C.C.) TRI-BEAD TAPE SEALER GABLE TRIM (GTM) RAKE SUPPORT (A-20-T) RAKE ANGLE (A-20-B)

1

1/4-14 X 1 1/4" SHOULDER (24" C.C.) * 1/4-14 X 1 1/4" SHOULDER (24" C.C.) * 1/4-14 X 1 1/4" WT (12" C.C.) RAKE SUPPORT (A-20-T) TRI-BEAD TAPE SEALER

BL

STC/MSC ROOF PANEL

THERMAL SPACER

(NOT BY CHIEF)

PURLIN

INSIDE CLOSURE

***

#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. For AP PANEL)

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) RAKE ANGLE (A-20-B) #12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) *** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.

(2) 1/4-14 X 7/8"

GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.) **OUTSIDE CLOSURE WALL PANEL GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)

* It is important that 1/4-14 X 1 1/4" shoulders are installed through the center of the slotted holes of the rake support.

**NOTE: Field cut outside closure for higher roof pitches.