STC MSC Roof Panel

MSC 2-Inch-Inset Gable Height Change-Field Bend Vertical Leg-Panel Below-Thermal Spacer

HEIGHT CHANGE ANGLE (A-20-H) #12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) *WALL PANEL

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL) TRI-BEAD TAPE SEALER HEIGHT CHANGE TRIM TOP (GHMTF) INSIDE CLOSURE

PURLIN

PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.

PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)

CLOSURE CLIPS (GCC-1) (TYP.)

BL

** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT. ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION. * FIELD CUT BOTTOM OF WALL PANELS TO MATCH

PURLIN CLOSURE (TYP.)

1/4-14 X 1 1/4" SHOULDER (24" C.C.)** RAKE SUPPORT (A-20-2)

PURLIN

1/4-14 X 1 1/4" WT (12" C.C.)

MSC ROOF PANEL(FIELD FORM 3" VERTICAL LEG TO FIT FINAL DIMENSION)

(2) 1/8" X 3/8" BLIND RIVETS (TYP.)

THERMAL SPACER

(NOT BY CHIEF)

(2) #12-14 X 1 1/4"' PER CLOSURE

1

4 "

PURLIN

TOP VIEW

HEIGHT CHANGE TRIM BOTTOM (GHMBF)

HEIGHT CHANGE RAFTER

2"

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)

RAKE ANGLE (A-20) 1/4-14 X 7/8" (12" C.C.) PANELING CAP TRIM (SCT) (2) #12-24 X 1 1/2" AT 36" C.C. PURLIN CLOSURE (GPC__) (PURLIN CLOSURE CLIPS NOT SHOWN)

NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.

EAVE STRUT

(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)

SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)

PURLIN CLOSURE INSTALLATION