STC MSC Roof Panel
MSC 2-Inch-Outset Gable Lead Height Change-Panel Below-Thermal Spacer
PURLIN
HEIGHT CHANGE ANGLE (A-20-H) #12-14 X 1 1/4" (TYP) (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) *WALL PANEL
PURLIN CLOSURE AT RIDGE IS TO BE FIELD CUT AND FASTENED TOGETHER WITH (2) 1/8" X 3/8" BLIND RIVETS.
PURLIN CLOSURE (GPC2 OR GPC3) (TYP) (2) PURLIN CLOSURE CLIPS (GCC1) AT EACH PURLIN CLOSURE (2) #12-14 X 1 1/4" EACH CLIP (2) 1/8" X 3/8" BLIND RIVETS (EACH CLIP)
CLOSURE CLIPS (GCC-1) (TYP.)
PURLIN CLOSURE (TYP.)
INSIDE CLOSURE HEIGHT CHANGE TRIM TOP (GHMTF) TRI-BEAD TAPE SEALER SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING) (SEE INSET DETAIL)
* FIELD CUT BOTTOM OF WALL PANELS TO MATCH ROOF SLOPE. PROVIDE AIR GAP OF 1/4" MIN. AT BOTTOM OF PANEL TO AVOID CORROSION.
BL
RAKE SUPPORT (A-20-2)
PURLIN
1/4-14 X 1 1/4" WT (12" C.C.) MSC ROOF PANEL THERMAL SPACER
PURLIN CLOSURE (PURLIN CLOSURE CLIPS NOT SHOWN)
(2) 1/8" X 3/8" BLIND RIVETS (TYP.)
1
4 "
** IT IS IMPORTANT THAT FASTENERS ARE INSTALLED THROUGH THE CENTER OF THE SLOTTED HOLES OF THE RAKE SUPPORT.
(NOT BY CHIEF)
(2) #12-14 X 1 1/4"' PER CLOSURE
TOP VIEW
PURLIN
HEIGHT CHANGE TRIM BOTTOM (GHMBF)
2"
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN)
1/4-14 X 1 1/4" SHOULDER (24" C.C.)**
NOTE: · Purlin closure is to be field cut between eave struts and purlins. · Closure clips may need to be field cut to fit in purlin and staggered so #12-14 X 1 1/4" fasteners don't interfere.
#12-14 X 1 1/4" (GA) (2 EACH PURLIN)
EAVE STRUT
RAKE ANGLE (A-20) HEIGHT CHANGE RAFTER 1/4-14 X 7/8" (12" C.C.) PANELING CAP TRIM (SCT)
(2) #12-14 X 1 1/4" (2) 1/8" X 3/8" BLIND RIVETS PURLIN CLOSURE CLIPS (GCC1)
SIKA 511 CAULK IN LOCKFORM OF HEIGHT CHANGE TRIM TOP (BEFORE ASSEMBLING)
PURLIN CLOSURE INSTALLATION
Made with FlippingBook flipbook maker