STC MSC Roof Panel
STC-MSC Gable Tail End and Thermal Spacer
TRI-BEAD TAPE SEALER 1/4-14 X 1 1/4" WT (12" C.C.) 1/4-14 X 1 1/4" SHOULDER (24" C.C.)* STC/MSC ROOF PANEL THERMAL SPACER
#12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL) RAKE ANGLE (A-20-B) RAKE SUPPORT (A-20-T) GABLE TRIM (GTMC)
BL
(NOT BY CHIEF)
(2) 1/4-14 X 7/8" INSIDE CLOSURE
***
*** DRAFTING NOTE: INSIDE CLOSURE MUST BE PROVIDED ON BUILDINGS WITH LINER INSULATION SYSTEM.
**OUTSIDE CLOSURE WALL PANEL 1/4-14 X 7/8" (12" C.C.) GABLE TRIM SUPPORT (GTS) (10'-0" C.C.) GABLE EXPANSION TRIM (GET)
#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN * It is important that 1/4-14 X 1 1/4" SHOULDERS are installed through the center of the slotted holes of the rake support.
** NOTE: Field cut outside closure for higher roof pitches.