STC MSC Roof Panel

STC-MSC Gable Tail End Termination Trim and Thermal Spacer

TERMINATION TRIM (GTTM) 1/4-14 X 1 1/4" WT (24" C.C.) 1/4-14 X 7/8" WT (6" C.C.) TRI-BEAD TAPE MASTIC GABLE TRIM (GTM) RAKE SUPPORT (A-20-T) RAKE ANGLE (A-20-B) #12-14 X 1 1/4" (6" C.C. for CS PANEL) (12" C.C. for AP PANEL)

*1/4-14 X 1 1/4" SHOULDER (24" C.C.) 1/4-14 X 1 1/4" WT (12" C.C. AND FASTEN THROUGH CLIP) TRI-BEAD TAPE MASTIC PANEL CLIP W/FASTENERS (REFER TO ROOF PANEL PLAN) STC/MSC ROOF PANEL

BL

****

THERMAL SPACER (NOT BY CHIEF)

INSIDE CLOSURE ***

(2) 1/4-14 X 7/8"

GABLE EXPANSION TRIM (GET) 1/4-14 X 7/8" (12" C.C.) WALL PANEL **OUTSIDE CLOSURE GABLE TRIM SUPPORT (GTS) (10'-0" C.C.)

#12-14 X 1" PANCAKE HEAD (2 EACH PURLIN) PURLIN

** Field cut outside closure for higher roof pitches. * It is important that 1/4-14 X 1 1/4" SHOULDER fasteners are installed through the center of the slotted holes of the rake support.

DRAFTING NOTES: *** Inside closure must be provided on buildings with liner insulation system. **** Thermal spacer to be used with no insulation.